Research approaches for studying flow-induced thromboembolic complications in blood recirculating devices
- 1 September 2004
- journal article
- review article
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 1 (1) , 65-80
- https://doi.org/10.1586/17434440.1.1.65
Abstract
The advent of implantable blood recirculating devices has provided life-saving solutions to patients with severe cardiovascular diseases. Recently it has been reported that ventricular assist devices are superior to drug therapy. The implantable total artificial heart is showing promise as a potential solution to the chronic shortage of available heart transplants. Prosthetic heart valves are routinely used for replacing diseased heart valves. However, all of these devices share a common problem--significant complications such as hemolysis and thromboembolism often arise after their implantation. Elevated flow stresses that are present in the nonphysiologic geometries of blood recirculating devices, enhance their propensity to initiate thromboembolism by chronically activating the blood platelets. This, rather than hemolysis, appears to be the salient aspect of blood trauma in devices. Limitations in characterizing and controlling relevant aspects of the flow-induced mechanical stimuli and the platelet response, hampers our ability to achieve design optimization for these devices. The main objective of this article is to describe state-of-the-art numerical, experimental, and in vivo tools, that facilitate elucidation of flow-induced mechanisms leading to thromboembolism in prosthetic devices. Such techniques are giving rise to an accountable model for flow-induced thrombogenicity, and to a methodology that has the potential to transform current device design and testing practices. It might lead to substantial time and cost savings during the research and development phase, and has the potential to reduce the risks that patients implanted with these devices face, lower the ensuing healthcare costs, and offer viable long-term solutions for these patients.Keywords
This publication has 107 references indexed in Scilit:
- Neurobehavioral Outcome Prediction After Cardiac SurgeryStroke, 2000
- Oxygen Inhalation Can Differentiate Gaseous From Nongaseous Microemboli Detected by Transcranial Doppler UltrasoundStroke, 1997
- Bigated Transcranial Doppler for the Detection of Clinically Silent Circulating Emboli in Normal Persons and Patients With Prosthetic Cardiac ValvesStroke, 1997
- A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesisJournal of Biomechanics, 1994
- Differentiation between gaseous and formed embolic materials in vivo. Application in prosthetic heart valve patients.Stroke, 1994
- Simulation of Transition with a Two-Equation Turbulence ModelAIAA Journal, 1994
- Experimental investigation of unsteady flow behaviour within a sac-type ventricular assist device (VAD)Journal of Biomechanics, 1993
- Detection of arterial emboli using Doppler ultrasound in rabbits.Stroke, 1991
- Estimation of the Rotational Undamped Natural Frequency of Bileaflet Cardiac Valve ProsthesesJournal of Biomechanical Engineering, 1990
- Turbulent Stresses in the Region of Aortic and Pulmonary ValvesJournal of Biomechanical Engineering, 1982