Continuous in vivo monitoring in diabetes: the subcutaneous glucose concentration
- 1 March 1995
- journal article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 39 (s104) , 21-29
- https://doi.org/10.1111/j.1399-6576.1995.tb04252.x
Abstract
The most advanced glucose sensors are measuring amperometrically the hydrogen peroxide generated in a stoichiometric relation to the prevailing glucose concentration during glucose oxidase‐mediated glucose oxidation. They proved useful in commercially available glucose analysers and in experimental subcutaneous (sc) monitoring. Here it is shown (a) that under steady state conditions the sc. glucose concentration is nearly identical to that in blood, (b) that sc. inserted glucose electrodes do mirror the intracorporal glucose concentration both under hypo‐, normo‐, and hyperglycaemic conditions with a clinically relevant accuracy, (c) that automated feedback control of intracorporal glucose concentration is possible applying the output of sc. glucose sensor as an input to the computer that controls the insulin pump, and (d) that stable function of sc. sensor may be accomplished over intervals up to one day; in some cases applications over up to ten days have been reported. The underlying problem consists in an insufficient functional biostability which is a function of biocompatibility and size of the sensor, of its sterility, and of the permanent skin penetration. The latter is still required to get the device in place, to keep it in function, and to make use of the data under any condition. At this time, sc. glucose electrodes to be employed as hypoglycaemia‐warning systems over one day are considered clinically important and technically achievable.Keywords
This publication has 34 references indexed in Scilit:
- Clinical Usefulness of the Glucose Concentration in the Subcutaneous Tissue - Properties and Pitfalls of Electrochemical BiosensorsHormone and Metabolic Research, 1994
- Evaluation of a Subcutaneous Glucose Sensor out to 3 Months in a Dog ModelDiabetes Care, 1994
- Enzymatic Glucose SensorsAsaio Journal, 1994
- Glucose Concentration in Subcutaneous Extracellular SpaceDiabetes Care, 1993
- Biocompatibility studies on plasm polymerized interface materials encompassing both hydrophobic and hydrophilic surfacesJournal of Biomedical Materials Research, 1992
- Noninvasive optical polarimetric glucose sensing using a true phase measurement techniqueIEEE Transactions on Biomedical Engineering, 1992
- Accuracy of Home Blood Glucose MonitorsDiabetes Care, 1992
- Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality?Journal of Biomedical Engineering, 1992
- Advances in the use of in vivo sensorsBiosensors and Bioelectronics, 1992
- ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERYAnnals of the New York Academy of Sciences, 1962