The spinal cord dura mater reaction to nitinol and titanium alloy particles: a 1-year study in rabbits
- 3 March 2007
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 16 (7) , 1063-1072
- https://doi.org/10.1007/s00586-007-0329-7
Abstract
This investigation was undertaken to simulate in an animal model the particles released from a porous nitinol interbody fusion device and to evaluate its consequences on the dura mater, spinal cord and nerve roots, lymph nodes (abdominal para-aortic), and organs (kidneys, spleen, pancreas, liver, and lungs). Our objective was to evaluate the compatibility of the nitinol particles with the dura mater in comparison with titanium alloy. In spite of the great use of metallic devices in spine surgery, the proximity of the spinal cord to the devices raised concerns about the effect of the metal debris that might be released onto the neural tissue. Forty-five New Zealand white female rabbits were divided into three groups: nitinol (treated: N = 4 per implantation period), titanium (treated: N = 4 per implantation period), and sham rabbits (control: N = 1 per observation period). The nitinol and titanium alloy particles were implanted in the spinal canal on the dura mater at the lumbar level L2–L3. The rabbits were sacrificed at 1, 4, 12, 26, and 52 weeks. Histologic sections from the regional lymph nodes, organs, from remote and implantation sites, were analyzed for any abnormalities and inflammation. Regardless of the implantation time, both nitinol and titanium particles remained at the implantation site and clung to the spinal cord lining soft tissue of the dura mater. The inflammation was limited to the epidural space around the particles and then reduced from acute to mild chronic during the follow-up. The dura mater, sub-dural space, nerve roots, and the spinal cord were free of reaction. No particles or abnormalities were found either in the lymph nodes or in the organs. In contact with the dura, the nitinol elicits an inflammatory response similar to that of titanium. The tolerance of nitinol by a sensitive tissue such as the dura mater during the span of 1 year of implantation demonstrated the safety of nitinol and its potential use as an intervertebral fusion device.Keywords
This publication has 35 references indexed in Scilit:
- 93. Spinal cord reaction to nitinol and titanium alloy particles: a 1-year study in rabbitsThe Spine Journal, 2003
- Histology of Tissues Within Retrieved Human Titanium Mesh CagesSpine, 2003
- Porous titanium‐nickel for intervertebral fusion in a sheep model: Part 2. Surface analysis and nickel release assessmentJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2003
- Porous titanium‐nickel for intervertebral fusion in a sheep model: Part 1. Histomorphometric and radiological analysis1Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2003
- The Effect of Titanium Particulate on Development and Maintenance of a Posterolateral Spinal ArthrodesisSpine, 2002
- Lumbar Interbody Fusion Using the Brantigan I/F Cage for Posterior Lumbar Interbody Fusion and the Variable Pedicle Screw Placement SystemSpine, 2000
- The Bagby and Kuslich Method of Lumbar Interbody FusionSpine, 1998
- A comparative analysis of fusion rates and donor-site morbidity for autogeneic rib and iliac crest bone grafts in posterior cervical fusionsJournal of Neurosurgery, 1998
- Iliac Crest Bone Graft Harvest Donor Site MorbiditySpine, 1995
- Subacute toxicity testing of biomaterials using histopathologic evaluation of rabbit muscle tissueJournal of Biomedical Materials Research, 1973