Potential of turbidity monitoring for measuring the transport of suspended solids in streams
- 1 January 1995
- journal article
- research article
- Published by Wiley in Hydrological Processes
- Vol. 9 (1) , 83-97
- https://doi.org/10.1002/hyp.3360090108
Abstract
Investigating the transport of suspended solids by water sampling usually leads to an underestimation of loads and an unrealistically high sampling frequency is required to properly characterize temporal trends. An alternative method is to use in situ optical turbidimeters to estimate the suspended solids concentration; however, the relationship between turbidity and suspended solids concentration is potentially confounded by variations in particle size, particle composition and water colour. Field measurements, and laboratory measurements using the type of natural material suspended in streamwater, were made to quantify the influences of these factors on nephelometric turbidity (Hach 2100A) and attenuance turbidity (Partech 7000 3RP MKII). The attenuance turbidity was approximately 2.5 times higher than nephelometric turbidity. The turbidity instruments were most sensitive to dispersions with a median diameter of 1.2‐1.4γm. Particle size variation can cause the turbidity to vary by a factor of four for the same concentration of suspended solids. However, the numerous close correlations between turbidity and suspended solids concentration reported previously suggests that either the particle size variations are not usually great, or that particle size variations are often associated with variations in suspended solids concentration. For the same concentration and particle size, organic particles gave attenuance turbidity values two to three times higher than mineral particles. However, shortterm temporal variations from purely organic to purely mineral particle loads are rare in nature, so variations in the percentage of organic matter in the paniculate load will not confound turbidity to this extent. Coloured dissolved organic matter is unlikely to alter the turbidity reading by more than 10%. An adequate relationship between turbidity measured in the field and suspended solids concentration should be expected in most situations. Some variance can be tolerated because a continuous estimate of suspended solids concentration overcomes the problem of infrequent sampling, which is the greatest source of error in the estimation of stream sediment loads.Keywords
This publication has 47 references indexed in Scilit:
- Hydrologic control of aluminum chemistry in an acidic headwater streamWater Resources Research, 1988
- SUSPENDED SEDIMENT AND TURBIDITY FOLLOWING ROAD CONSTRUCTION AND LOGGING IN WESTERN MONTANA1Jawra Journal of the American Water Resources Association, 1987
- Averages from Turbidity MeasurementsPublished by American Chemical Society (ACS) ,1987
- Spatial and Temporal Variation of the Particle-Size Characteristics of Fluvial Suspended SedimentGeografiska Annaler: Series A, Physical Geography, 1987
- RED ALDER LEAF LITTER AND STREAMWATER QUALITY IN WESTERN OREGON1Jawra Journal of the American Water Resources Association, 1986
- Field calibration of a recording turbidity meterCATENA, 1985
- Some observations on suspended sediment dynamics in Storbregrova, JotunheimenEarth Surface Processes and Landforms, 1984
- Relationships among dissolved organic matter, iron, and discharge in a moorland streamEarth Surface Processes and Landforms, 1984
- Suspended solids concentrations and river water chemistryEarth Surface Processes and Landforms, 1981
- Continuous recording of suspended solids in effluentsJournal of Scientific Instruments, 1962