Ropivacaine, 0.1%, Plus Sufentanil, 0.5 μg/ml, versus Bupivacaine, 0.1%, Plus Sufentanil, 0.5 μg/ml, Using Patient-controlled Epidural Analgesia for Labor
- 1 June 2000
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 92 (6) , 1588-1593
- https://doi.org/10.1097/00000542-200006000-00015
Abstract
Background: This study compared the administration of 0.1% ropivacaine and 0.5 microg/ml sufentanil with that of 0.1% bupivacaine and 0.5 microg/ml sufentanil via patient-controlled epidural analgesia route during labor. Methods: Two hundred healthy pregnant women at term with a single fetus with a vertex fetal presentation were randomized in a double-blind fashion to receive either 0.1% ropivacaine and 0.5 microg/ml sufentanil or 0.1% bupivacaine and 0.5 microg/ml sufentanil using a patient-controlled epidural analgesia pump (5-ml bolus dose, 10-min locked-out period, no basal infusion). Pain score on a visual analog scale, Bromage score (0-3), level of sensory block, patient-controlled epidural analgesia ratio, drug use, supplemental boluses, and side effects were recorded at 30 min and then hourly. Mode of delivery, duration of first and second stages of labor, umbilical cord pH, Apgar scores of the newborn, and a measure of maternal satisfaction were recorded after delivery. Results: No differences were seen between the two groups for pain scores on a visual analog scale during labor, volume of anesthetic solution used, mode of delivery, or side effects. Motor block during the first stage of labor was significantly less in the ropivacaine group than in the bupivacaine group (no motor block in 97.8 of patients vs. 88.3%, respectively; P < 0.01). Duration of the second stage of labor was shorter in the ropivacaine group (1.3 +/- 1.0 vs. 1.5 +/- 1.2 h [mean +/- SD]; P < 0.05). Maternal satisfaction was greater in the bupivacaine group (91 +/- 13 mm for contraction, 89 +/- 19 mm for delivery on a visual scale: 0 = not satisfied at all, 100 = fully satisfied) than in the ropivacaine group (84 +/- 21 and 80 +/- 25 mm; P < 0.0001). Patients in the ropivacaine group requested more supplemental boluses to achieve analgesia during the second stage of labor than those in the bupivacaine group (29.7 vs. 19.8%, respectively, requested one or more supplemental boluses; P < 0.05). Conclusions: Delivered as patient-controlled epidural analgesia, 0.1% ropivacaine and 0.5 microg/ml sufentanil produce less motor block but are clinically less potent than 0.1% bupivacaine and 0.5 microg/ml sufentanil.Keywords
This publication has 11 references indexed in Scilit:
- Relative Analgesic Potencies of Ropivacaine and Bupivacaine for Epidural Analgesia in LaborAnesthesiology, 1999
- A Double-blind Comparison of 0.125% Ropivacaine with Sufentanil and 0.125% Bupivacaine with Sufentanil for Epidural Labor AnalgesiaAnesthesiology, 1999
- Relative potencies of bupivacaine and ropivacaine for analgesia in labourBritish Journal of Anaesthesia, 1999
- Neonatal outcome and mode of delivery after epidural analgesia for labour with ropivacaine and bupivacaine: a prospective meta-analysisBritish Journal of Anaesthesia, 1998
- 0.125% Ropivacaine Is Similar to 0.125% Bupivacaine for Labor Analgesia Using Patient-Controlled Epidural InfusionAnesthesia & Analgesia, 1998
- Continuous extradural infusion of ropivacaine 2 mg ml-1 for pain relief during labourBritish Journal of Anaesthesia, 1997
- Double-blind comparison of epidural ropivacaine 0.25% and bupivacaine 0.25%, for the relief of childbirth painCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1997
- A double-blind comparison of 0.25% ropivacaine and 0.25% bupivacaine for extradural analgesia in labourBritish Journal of Anaesthesia, 1996
- Comparison of ropivacaine and bupivacaine in extradural analgesia for the relief of pain in labourBritish Journal of Anaesthesia, 1995
- Ropivacaine 0.25% Versus Bupivacaine 0.25% for Continuous Epidural Analgesia in LaborAnesthesia & Analgesia, 1995