Controlled evaluation of 5 versus 10 milliliters of blood cultured in aerobic BacT/Alert blood culture bottles
- 1 September 1994
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 32 (9) , 2103-6
- https://doi.org/10.1128/jcm.32.9.2103-2106.1994
Abstract
Bottles developed for use in the BacT/Alert automated blood culture system (Organon Teknika Corp., Durham, N.C.) can accept up to 10 ml of blood without falling below a 1:5 ratio of blood to broth. We compared the yield and speed of detection of microorganisms in 13,128 adequately filled, paired, aerobic bottles inoculated with 5 versus 10 ml of blood at three university hospitals. A total of 798 microorganisms causing sepsis grew in one or both bottles. The overall recovery of microorganisms from 10-ml samples exceeded that from 5-ml samples (P < 0.001); the increased yield attributed to the additional 5 ml in the samples was 7.2%. The increased yield from 10-ml inocula was most marked for Escherichia coli (P < 0.01) and other members of the family Enterobacteriaceae (P < 0.001). Ten-milliliter samples did not yield more gram-positive bacteria, nonfermentative gram-negative rods, or yeasts. When both bottles were positive, the bottles inoculated with 10 ml of blood showed growth sooner (P < 0.001). Earlier detection with 10-ml inocula was especially notable for coagulase-negative staphylococci (P < 0.001), streptococci (P < 0.001), E. coli (P < 0.025), and other members of the family Enterobacteriaceae (P < 0.025). We conclude that an increase in the volume of blood inoculated into BacT/Alert aerobic blood culture bottles from 5 to 10 ml will increase the overall yield and the speed of detection of clinically important blood pathogens.Keywords
This publication has 7 references indexed in Scilit:
- Detection of Bacteremia in Adults: Consequences of Culturing an Inadequate Volume of BloodAnnals of Internal Medicine, 1993
- Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.1992
- Diagnostic DecisionAnnals of Internal Medicine, 1987
- Blood Cultures: Issues and ControversiesClinical Infectious Diseases, 1986
- Specimen volume versus yield in the BACTEC blood culture systemJournal of Clinical Microbiology, 1985
- The Clinical Significance of Positive Blood Cultures: A Comprehensive Analysis of 500 Episodes of Bacteremia and Fungemia in Adults. I. Laboratory and Epidemiologic ObservationsClinical Infectious Diseases, 1983
- Studies on the Bacteremia of Bacterial EndocarditisJAMA, 1967