Comparative Lifetesting Results for Microchannel Plates in Windowless EUV Photon Detectors
- 1 January 1984
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 31 (1) , 404-407
- https://doi.org/10.1109/tns.1984.4333287
Abstract
Microchannel plates (MCP's) from seven manufacturers were subjected to a series of tests to determine their suitability for the Extreme Ultraviolet Explorer satellite. Comparative data are presented for sixteen MCP tandem pairs with channel length to diameter ratios (I/d's) ranging from 40:1 to 60:1 and for two saturable (curved channel) MCP's with I/d's of 80:1. Results for MCP's with funnelled channel throats are also discussed. Properties of the MCP's which were monitored include: background count rate, output charge pulse height distribution (PHD), modal gain, PHD full width half maximum (FWHM), and extreme ultraviolet (EUV) photon quantum efficiency. Five detectors were chosen for further lifetime testing consisting of a mild bake to 100°C, and charge extraction to 10-2 coulombs, repeated high voltage cycling and reexposure to one atmosphere conditions. The results of these tests and their implications for the flight detectors are discussed. Erratic events in the detector background were recorded, probably due to field emission from high voltage surfaces or the absorption of water vapor into the electrode following exposure to air. The steps taken to control the detector background are discussed.Keywords
This publication has 11 references indexed in Scilit:
- Maximizing the quantum efficiency of microchannel plate detectors: The collection of photoelectrons from the interchannel web using an electric fieldReview of Scientific Instruments, 1983
- Application of the Wedge and Strip Anode to Position Sensing with Microchannel Plates and Proportional CountersIEEE Transactions on Nuclear Science, 1983
- The Gain Characteristics of Microchannel Plates for X-Ray Photon CountingIEEE Transactions on Nuclear Science, 1983
- Quantum efficiency of opaque CsI photocathodes with channel electron multiplier arrays in the extreme and far ultravioletApplied Optics, 1982
- Curved-channel microchannel array platesReview of Scientific Instruments, 1981
- Microchannel plate life testsApplied Optics, 1977
- Areal detection efficiency of channel electron multiplier arraysReview of Scientific Instruments, 1976
- Review of the Influence of Radiations on Channeltrons and Channel PlatesIEEE Transactions on Nuclear Science, 1976
- Reversibility of parameter changes of microchannel electron multipliers due to outgassingReview of Scientific Instruments, 1974