Ultimate intrinsic signal‐to‐noise ratio in MRI
- 1 March 1998
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 39 (3) , 462-473
- https://doi.org/10.1002/mrm.1910390317
Abstract
A method to calculate the ultimate intrinsic signal‐to‐noise ratio (SNR) in a magnetic resonance experiment for a point inside an arbitrarily shaped object is presented. The ultimate intrinsic SNR is determined by body noise. A solution is obtained by optimizing the electromagnetic field to minimize total power deposition while maintaining a constant right‐hand circularly polarized component of the magnetic field at the point of interest. A numerical approximation for the optimal field is found by assuming a superposition of a large number of plane waves. This simulation allowed estimation of the ultimate intrinsic SNR attainable in a human torso model. The performance of six coil configurations was evaluated by comparing the SNR of images obtained by the coils with the ultimate values. In addition, the behavior of ultimate intrinsic SNR was investigated as a function of main field strength. It was found that the ultimate intrinsic SNR increases better than linearly with the main magnetic field up to 10 T for our model. It was observed that for field strengths of 4 T or higher, focusing is required to reach the ultimate intrinsic SNR.Keywords
This publication has 9 references indexed in Scilit:
- What is the optimum phased array coil design for cardiac and torso magnetic resonance?Magnetic Resonance in Medicine, 1997
- The signal-to-noise ratio of nuclear magnetic resonance surface coils and application to a lossy dielectric cylinder model. I. TheoryIEEE Transactions on Biomedical Engineering, 1995
- Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils [magnetic resonance imaging]IEEE Transactions on Biomedical Engineering, 1995
- The NMR phased arrayMagnetic Resonance in Medicine, 1990
- The intrinsic signal‐to‐noise ratio in NMR imagingMagnetic Resonance in Medicine, 1986
- Measurement of signal intensities in the presence of noise in MR imagesMedical Physics, 1985
- The sensitivity of the zeugmatographic experiment involving human samplesJournal of Magnetic Resonance (1969), 1979
- RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imagingPhysics in Medicine & Biology, 1978
- New plane wave spectrum formulations for the near-fields of circular and strip aperturesIEEE Transactions on Antennas and Propagation, 1976