Attenuation correction of PET cardiac data with low‐dose average CT in PET/CT
- 27 September 2006
- journal article
- nuclear medicine-physics
- Published by Wiley in Medical Physics
- Vol. 33 (10) , 3931-3938
- https://doi.org/10.1118/1.2349843
Abstract
We proposed a low‐dose average computer tomography (ACT) for attenuation correction (AC) of the PET cardiac data in PET/CT. The ACT was obtained from a cine CT scan of over one breath cycle per couch position while the patient was free breathing. We applied this technique on four patients who underwent tumor imaging with in PET/CT, whose PET data showed high uptake of in the heart and whose CT and PET data had misregistration. All four patients did not have known myocardiac infarction or ischemia. The patients were injected with of and scanned after injection. The helical CT (HCT) data were acquired in for the coverage of . The PET acquisition was per bed of . The duration of cine CT acquisition per was . We used a fast gantry rotation cycle time of to minimize motion induced reconstruction artifacts in the cine CT images, which were averaged to become the ACT images for AC of the PET data. The radiation dose was about for cine duration. The selection of was based on our analysis of the respiratory signals of 600 patients; 87% of the patients had average breath cycles of less than and 90% had standard deviations of less than in the period of breath cycle. In all four patient studies, registrations between the CT and the PET data were improved. An increase of average uptake in the anterior and the lateral walls up to 48% and a decrease of average uptake in the septal and the inferior walls up to 16% with ACT were observed. We also compared ACT and conventional slow scan CT (SSCT) of duration in one patient study and found ACT was better than SSCT in depicting average respiratory motion and the SSCT images showed motion‐induced reconstruction artifacts. In conclusion, low‐dose ACT improved registration of the CT and the PET data in the heart region in our study of four patients. ACT was superior than SSCT for depicting average respiration motion in a patient study.Keywords
This publication has 16 references indexed in Scilit:
- Respiratory gating of cardiac PET data in list-mode acquisitionEuropean Journal of Nuclear Medicine and Molecular Imaging, 2006
- Four‐dimensional (4D) PET/CT imaging of the thoraxMedical Physics, 2004
- Prognostic validation of a 17-segment score derived from a 20-segment score for myocardial perfusion SPECT interpretationJournal of Nuclear Cardiology, 2004
- Quantitation of respiratory motion during 4D‐PET/CT acquisitionMedical Physics, 2004
- Radiation exposure during transmission measurements: comparison between CT- and germanium-based techniques with a current PET scannerEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- American society of nuclear cardiology practice guidelinesJournal of Nuclear Cardiology, 2003
- Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancerMedical Physics, 2002
- Multiple “slow” CT scans for incorporating lung tumor mobility in radiotheraphy planningInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Attenuation correction for a combined 3D PET/CT scannerMedical Physics, 1998
- Real-time system for respiratory-cardiac gating in positron tomographyIEEE Transactions on Nuclear Science, 1998