X-ray microtomography of biological tissues using laboratory and synchrotron sources
- 1 August 1987
- journal article
- Published by Springer Nature in Biological Trace Element Research
- Vol. 13 (1) , 219-227
- https://doi.org/10.1007/bf02796634
Abstract
X-ray microradiography is a well established technique for the study of biological structures in which the projected absorption is measured, usually with photographic film or resist. If scanning X-ray microradiography with a 15-μm beam, 2-D scanning, and photon counting is used, more accurate results can be obtained and real-time experiments undertaken. Addition of a rotation axis allows computerized axial tomography to be done at a resolution of 15 μm. This technique overcomes the inherent difficulty of microradiography that all detail perpendicular to the plane of the specimen is superimposed. This method has been applied to the study of the 3-D mineral distribution in a 0.8×0.8 mm column of human cortical bone with a laboratory X-ray source. Calculation of the wavelength dependence of the linear absorption coefficient for liver and bone shows that, for a choice of wavelength in the range of 3–0.4 Å (4–30 keV), the specimen thickness can be from 100μm–2 cm and 10 μm–3 mm, respectively. Synchrotron X-radiation has the potential for better resolution because of the higher intensity, which allows the use of a narrower beam. There is also the possibility of determining individual element 3-D distributions from measurements on either side of the absorption edges because of the continuous nature of the spectrum and also the possibility of doing this from X-ray fluorescence measurements. To investigate these possibilities, a tomographic apparatus has been built based on the availability of accurately ground, tungsten carbide balls. Metrological assessment shows that the specimen remains within <1 μm of the required position during translation and rotation. Preliminary X-ray tomographic studies with a 4-μm diameter beam have been started at the Daresbury laboratory synchrotron source.Keywords
This publication has 11 references indexed in Scilit:
- X-ray Microtomography with Synchrotron RadiationPublished by SPIE-Intl Soc Optical Eng ,1986
- X‐ray microscopy using computerized axial tomographyJournal of Microscopy, 1985
- Soft x-ray microscopesReview of Scientific Instruments, 1985
- Scanning X-Ray Microradiographic Study of the Formation of Caries-Like Lesions in Synthetic Apatite AggregatesCaries Research, 1985
- Recent developments in the industrial application of computerized tomography with ionizing radiationNDT International, 1984
- Critical absorption tomography of small samples: Proposed applications of synchrotron radiation to computerized tomography IINuclear Instruments and Methods in Physics Research, 1983
- Optimum energies for x-ray transmission tomography of small samples: Applications of synchrotron radiation to computerized tomography INuclear Instruments and Methods in Physics Research, 1983
- SOME EXPERIENCES WITH X‐RAY AND PROTON MICROSCOPES*Annals of the New York Academy of Sciences, 1978
- Computerized transverse axial scanning (tomography): Part 1. Description of systemThe British Journal of Radiology, 1973
- A Scanning X-Ray Microscope Using Synchrotron RadiationScience, 1972