Hemodynamic and Gas Transfer Properties of a Compliant Thoracic Artificial Lung
- 1 July 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 51 (4) , 404-411
- https://doi.org/10.1097/01.mat.0000169707.72242.8f
Abstract
A compliant thoracic artificial lung (TAL) has been developed for acute respiratory failure or as a bridge to transplantation. The development goal was to increase TAL compliance, lower TAL impedance, and improve right ventricular function during use. Prototypes were tested in vitro and in vivo in eight pigs between 67 and 79 kg to determine hemodynamic and gas transfer properties. The in vitro compliance was 16.2 +/- 4.4 ml/mm Hg at pressures < 7.8 mm Hg and 4.3 +/- 1.1 ml/mm Hg above 7.8 mm Hg. In vivo, this compliance significantly reduced blood flow pulsatility from 1.7 at the inlet to 0.36 at the outlet. Device resistance was 1.9 and 1.8 mm Hg/(L/min) at a flow rate of 4 L/min in vitro and in vivo, respectively. Approximately 75% of the resistance was at the inlet and outlet. In vivo TAL O2 and CO2 transfer rates were 188 and 186 ml/min, respectively, at 4 L/min of blood and gas flow, and average outlet O2 saturations exceeded 98% for average flow rates up to and including the maximum tested, 5.3 L/min. The new design has a markedly improved compliance and excellent gas transfer but also possesses inlet and outlet resistances that must be reduced in future designs.Keywords
This publication has 10 references indexed in Scilit:
- In Vivo Hemodynamic Responses to Thoracic Artificial Lung AttachmentAsaio Journal, 2005
- DESIGN OF AN ARTIFICIAL LUNG COMPLIANCECHAMBER FOR RIGHT VENTRICLAR FUNCTIONAsaio Journal, 2004
- DETERMINATION OF IDEAL THORACIC ARTIFICIAL LUNG COMPLIANCE AT VARIOUS RIGHT VENTRICULAR OUTPUTSAsaio Journal, 2004
- Blood Flow Pulsatility Effects upon Oxygen Transfer in Artificial LungsAsaio Journal, 2003
- Design of an Artificial Lung Compliance Chamber for Pulmonary ReplacementAsaio Journal, 2003
- The paracorporeal artificial lung improves 5-day outcomes from lethal smoke/burn-induced acute respiratory distress syndrome in sheepThe Annals of Thoracic Surgery, 2002
- Improved right heart function with a compliant inflow artificial lung in series with the pulmonary circulationThe Annals of Thoracic Surgery, 2001
- Testing of an Intrathoracic Artificial Lung in a Pig ModelPublished by Wolters Kluwer Health ,1996
- Use of a Mathematical Model to Predict Oxygen Transfer Rates in Hollow Fiber Membrane OxygenatorsAsaio Journal, 1994
- Pressure-flow relations in coronary circulationPhysiological Reviews, 1990