Thin Layer Chromatography as a Routine Appropriate Technique for the Determination of Bipyridylium Herbicides in Post Mortem Human Tissues
- 1 January 1982
- journal article
- research article
- Published by SAGE Publications in Medicine, Science and the Law
- Vol. 22 (1) , 57-62
- https://doi.org/10.1177/002580248202200111
Abstract
A thin layer chromatographic procedure for the detection of bipyridylium compounds in post-mortem human tissues is described. To verify the suitability of the method, human biological samples originating from two fatal poisoning cases, are analyzed. In the first case, an amount of Gramoxone® (Paraquat) was taken orally. Death occurred after ± 30 hours without any specific treatment. The second case is concerned with an ingestion of Reglone® (Diquat), followed by death after 5 days of intensive care treatment.Keywords
This publication has 4 references indexed in Scilit:
- Spectrophotometric method for the determination of paraquatThe Analyst, 1979
- A Rapid and Sensitive Assay for the Determination of Paraquat in Plasma by Gas-Liquid ChromatographyJournal of Analytical Toxicology, 1977
- The analysis of paraquat in urine by high-speed liquid chromatographyJournal of Chromatography A, 1975
- A rapid method for the simultaneous determination of paraquat and diquat in pond and river waters by pyrolysis and gas chromatographyThe Analyst, 1975