GC/FT-IR Experimental Considerations in the Separation of Complex Hydrocarbon Mixtures Using Fused Silica Columns
- 1 May 1984
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 38 (3) , 366-370
- https://doi.org/10.1366/0003702844555458
Abstract
The successful interfacing and utilization of fused silica capillary GC columns with Fourier transform infrared spectrometry (FT-IR) can introduce difficulties not usually encountered with lower efficiency (higher capacity) GC columns. Recognition of these difficulties, however, can lead to refinement of a GC/FT-IR detection system which can analyze complex samples with low nanogram detection limits. Chromatographic and spectrometric considerations include lightpipe temperature, choice of sample introduction, column concentration dynamic range capability, infrared data acquisition rate, and spectral S/N ratio. These parameters as they relate to capillary GC/FT-IR method development are discussed. The GC/FT-IR analysis of a complex sample is presented in an effort to explain these problems. In order to reflect the FT-IR sensitivity under complex sample chromatographic conditions, quantification data using known compounds are also included.Keywords
This publication has 13 references indexed in Scilit:
- Mixture analysis by gas chromatography/Fourier transform infrared spectrometry/mass spectrometryAnalytical Chemistry, 1982
- The Capability of GC/FT-IR to Identify Toxic Substances in Environmental Sample ExtractsJournal of Chromatographic Science, 1982
- Organic analysis with a combined capillary gas chromatograph mass spectrometer Fourier transform infrared spectrometerAnalytical Chemistry, 1982
- WCOT Capillary Column GC/FT-IR and GC/MS for Identifying Toxic Organic PollutantsApplied Spectroscopy, 1981
- An integrated GC/FT‐IR system for the analysis of environmental pollutantsJournal of High Resolution Chromatography, 1981
- Identification of Peaks in Capillary Column Gas Chromatograms at the Nanogram Level by Dual-Beam Fourier Transform Infrared SpectrometryApplied Spectroscopy, 1980
- Advancing the chromatography of GC/FT‐IR to WCOT capillary columnsJournal of High Resolution Chromatography, 1980
- Application of the Combined Analytical Techniques of HPLC/FT-IR, GC/FT-IR, and GC/MS to the Analysis of Real SamplesJournal of Chromatographic Science, 1979
- An investigation of glasses for capillary chromatographyJournal of High Resolution Chromatography, 1979
- On Line Infrared Identification of Gas Chromatography EffluentsApplied Spectroscopy, 1975