Energy Expenditure Estimated by Accelerometry and Doubly Labeled Water
- 1 December 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 38 (12) , 2165-2172
- https://doi.org/10.1249/01.mss.0000235883.94357.95
Abstract
The purpose of this study was to compare energy expenditure derived from regression equations determined from accelerometry with energy expenditure obtained from the doubly labeled water method (DLW). Thirteen subjects participated in a 7-d protocol during which total daily energy expenditure (TDEE) was measured with DLW. Simultaneously, during the 7 d, subjects wore a Tritrac-R3D and an Actigraph (ACT). Pearson and concordance correlations and one-sample t-tests were used to determine the agreement of six Tritrac and eight ACT regression equations that convert body acceleration to energy expenditure with the DLW measurements. Tritrac TDEE determined from the different Tritrac regression equations under- and overestimated TDEE determined with DLW that ranged from -10 to +101%. For ACT, the percent difference between DLW and ACT-TDEE determined with the regression equation developed by Hendelman and Swartz were not statistically significantly different from zero. The mean of the difference was -2 and -4%, but the range of the difference was large for both equations, -29 to +24%. TDEE determined with the six other ACT equations were significantly different compared with DLW. Of the 14 different regression equations from the literature, only two developed for ACT compared favorably with DLW; however, the difference in TDEE between these two methods was variable and rather large. These results reemphasize the difficulty in converting body movement into energy expenditure on an individual basis from accelerometry. These results imply that researchers may want to avoid using accelerometers to predict energy expenditure in free-living conditions, instead using these instruments only to measure patterns of physical activity.Keywords
This publication has 20 references indexed in Scilit:
- A novel method for using accelerometer data to predict energy expenditureJournal of Applied Physiology, 2006
- Accelerometer Data Reduction: A Comparison of Four Reduction Algorithms on Select Outcome VariablesMedicine & Science in Sports & Exercise, 2005
- Metabolic equivalent: one size does not fit allJournal of Applied Physiology, 2005
- Comparison of MTI Accelerometer Cut-Points for Predicting Time Spent in Physical ActivityInternational Journal of Sports Medicine, 2003
- Ability of Different Physical Activity Monitors to Detect Movement During Treadmill WalkingInternational Journal of Sports Medicine, 2003
- Effect of Monitor Placement and of Activity Setting on the MTI Accelerometer OutputMedicine & Science in Sports & Exercise, 2003
- Validity of four motion sensors in measuring moderate intensity physical activityMedicine & Science in Sports & Exercise, 2000
- Determinants of 24-hour energy expenditure in man. Methods and results using a respiratory chamber.Journal of Clinical Investigation, 1986
- Estimating Human Energy Expenditure Using An Accelerometer DeviceJournal of Clinical Engineering, 1984