3He‐MRI‐based vs. conventional determination of lung volumes in patients after unilateral lung transplantation: a new approach to regional spirometry
- 24 July 2002
- journal article
- research article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 46 (7) , 845-852
- https://doi.org/10.1034/j.1399-6576.2002.460715.x
Abstract
Background: To use 3Helium (3He)‐MRI in patients with unilateral lung grafts to assess the contributions of graft and native lung to total ventilated lung volume, and second to compare conventional measurements of intrapulmonary gas volume (spirometry, body plethysmography) with image‐based volumetry of ventilated lung parenchyma visualized by hyperpolarized 3He‐MRI. Methods: With Ethics Committee approval, five patients with single lung transplantation (SLTX) for idiopathic pulmonary fibrosis (IPF) underwent both conventional pulmonary function testing (PFT) and 3He‐MRI of the lung. Intrapulmonary gas volume (GV) during the inspiratory breathhold for 3He‐MRI was calculated from measured functional residual capacity (corrected for supine position) and inspired tidal volume. Image‐based global and regional lung volumetries (LV) were performed in three‐dimensionally reconstructed 3He‐MR images (corrected for the fraction of tissue and blood). Results: Transplanted lungs were characterized by a homogeneous distribution of signal intensity, whereas the native lungs of the patients suffering from IPF displayed an inhomogeneous signal distribution pattern with numerous round or wedge‐shaped ventilation defects. Total ventilated lung volume determined by 3He‐MRI correlated well with PFT‐based measurements, but with a systematic overestimation of the 3He‐based lung volumetry of approximately 20%. Functioning lung grafts contributed 66±6% and their corresponding native IPF lungs 34±6% to total ventilated volume (P<0.05; mean±SD). Conclusion: 3Helium‐MRI of the lung offers a novel approach to regional determination of ventilated lung volume, including its blood and tissue compartments. The advantage of this technique over computed tomography or ventilation scintigraphy is the lack of radiation exposure, and hence its repeatability. Follow up of SLTX patients with this new technique may allow the monitoring of functional and structural developments of grafted lungs with better sensitivity and specificity than PFT.Keywords
This publication has 16 references indexed in Scilit:
- Volumetry of Ventilated Airspaces by 3He MRIInvestigative Radiology, 2001
- Ultraschnelle MRT der Lungenventilation mittels hochpolarisiertem Helium-3*RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2000
- Analysis of intrapulmonary O2concentration by MR imaging of inhaled hyperpolarized helium-3Journal of Applied Physiology, 1999
- Quantification of Regional Intrapulmonary Oxygen Partial Pressure Evolution during Apnea by 3He MRIJournal of Magnetic Resonance, 1999
- MRI using hyperpolarized noble gasesEuropean Radiology, 1998
- Imaging of the lungs using 3he MRI: Preliminary clinical experience in 18 patients with and without lung diseaseJournal of Magnetic Resonance Imaging, 1997
- Normal and abnormal pulmonary ventilation: visualization at hyperpolarized He-3 MR imaging.Radiology, 1996
- Human lung air spaces: potential for MR imaging with hyperpolarized He-3.Radiology, 1996
- Nuclear magnetic resonance imaging of airways in humans with use of hyperpolarized 3HeMagnetic Resonance in Medicine, 1996
- Optimal assessment and management of chronic obstructive pulmonary disease (COPD). The European Respiratory Society Task ForceEuropean Respiratory Journal, 1995