Real‐time cardiac MRI at 3 tesla
- 26 March 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 51 (4) , 655-660
- https://doi.org/10.1002/mrm.20053
Abstract
Real‐time cardiac and coronary MRI at 1.5T is relatively “signal starved” and the 3T platform is attractive for its immediate factor of two increase in magnetization. Cardiac imaging at 3T, however, is both subtly and significantly different from imaging at 1.5T because of increased susceptibility artifacts, differences in tissue relaxation, and RF homogeneity issues. New RF excitation and pulse sequence designs are presented which deal with the fat‐suppression requirements and off‐resonance issues at 3T. Real‐time cardiac imaging at 3T is demonstrated with high blood SNR, blood‐myocardium CNR, resolution, and image quality, using new spectral‐spatial RF pulses and fast spiral gradient echo pulse sequences. The proposed sequence achieves 1.5 mm in‐plane resolution over a 20 cm FOV, with a 5.52 mm measured slice thickness and 32 dB of lipid suppression. Complete images are acquired every 120 ms and are reconstructed and displayed at 24 frames/sec using a sliding window. Results from healthy volunteers show improved image quality, a 53% improvement in blood SNR efficiency, and a 232% improvement in blood‐myocardium CNR efficiency compared to 1.5T. Magn Reson Med 51:655–660, 2004.Keywords
This publication has 17 references indexed in Scilit:
- Real‐time interactive coronary MRAMagnetic Resonance in Medicine, 2001
- Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging systemJournal of the American College of Cardiology, 2001
- Design of improved spectral-spatial pulses for routine clinical useMagnetic Resonance in Medicine, 2000
- Function: Magnetic Resonance Real-Time Imaging for the Evaluation of Left Ventricular FunctionJournal of Cardiovascular Magnetic Resonance, 2000
- Simulation ofB1Field Distribution and Intrinsic Signal-to-Noise in Cardiac MRI as a Function of Static Magnetic FieldJournal of Magnetic Resonance, 1997
- Optimized gradient waveforms for spiral scanningMagnetic Resonance in Medicine, 1995
- Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)IEEE Transactions on Medical Imaging, 1991
- Simultaneous spatial and spectral selective excitationMagnetic Resonance in Medicine, 1990
- MR fluoroscopy: Technical feasibilityMagnetic Resonance in Medicine, 1988
- Variable-rate selective excitationJournal of Magnetic Resonance (1969), 1988