Background— In patients with coronary artery stents, no direct noninvasive coronary artery imaging is possible with magnetic resonance (MR). A well-established method for the assessment of the functional significance of a coronary lesion is the measurement of coronary flow reserve by invasive intracoronary Doppler. The purpose of the study was to determine coronary flow velocity reserve (CFVR) with MR after stent deployment. Methods and Results— Thirty-eight patients after successful PTCA and stent deployment were included. CFVR was measured perpendicular to the artery distal to the stent using phase-contrast velocity quantification at rest and during adenosine-stimulated hyperemia with a 1.5T MR tomograph (ACS NT, Philips). Measurements were repeated after 3 months and compared with invasive coronary angiography. In 18 patients, additional invasive Doppler flow measurements were obtained. CFVR could be determined in 29 of 38 (76%) of the patients. After 3 months, significant differences were obtained bet...Keywords
This publication has 21 references indexed in Scilit:
- Measurement of Coronary Blood Flow and Flow Reserve Using Magnetic Resonance ImagingCardiology, 1997
- Assessment of flow in the right human coronary artery by magnetic resonance phase contrast velocity measurement: Effects of cardiac and respiratory motionMagnetic Resonance in Medicine, 1996
- Validation of volume flow measurements with cine phase‐contrast MR imaging for peripheral arterial waveformsJournal of Magnetic Resonance Imaging, 1995
- Assessment of magnetic resonance velocity mapping of global ventricular function during dobutamine infusion in coronary artery disease.Heart, 1995
- In Vivo Validation of Magnetic Resonance Blood Volume Flow Measurements with Limited Spatial Resolution in Small VesselsMagnetic Resonance in Medicine, 1995
- The application of breath hold phase velocity mapping techniques to the measurement of coronary artery blood flow velocity: Phantom data and initial in vivo resultsMagnetic Resonance in Medicine, 1994
- Flow velocity quantification in human coronary arteries with fast, breath‐hold MR angiographyJournal of Magnetic Resonance Imaging, 1993
- Magnetic Resonance Imaging of Blood Flow with a Phase Subtraction TechniqueInvestigative Radiology, 1993
- Three‐dimensional phase contrast angiographyMagnetic Resonance in Medicine, 1989
- Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference TechniqueJournal of Computer Assisted Tomography, 1984