Noisy pressure support ventilation: A pilot study on a new assisted ventilation mode in experimental lung injury*
- 1 March 2008
- journal article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 36 (3) , 818-827
- https://doi.org/10.1097/01.ccm.0000299736.55039.3a
Abstract
To describe and evaluate the effects of the new noisy pressure support ventilation (noisy PSV) on lung physiologic variables. Crossover design with four modes of mechanical ventilation. Experimental research facility of a university hospital. A total of 12 pigs weighing 25.0–36.5 kg. Animals were anesthetized, the trachea was intubated, and lungs were ventilated with a mechanical ventilator (volume-controlled mode). Acute lung injury was then induced by surfactant depletion. Biphasic intermittent airway pressure/airway pressure release ventilation (BIPAP/APRV) was initiated, and anesthesia depth was decreased to allow spontaneous breathing. After that, each animal was ventilated with four different modes of assisted mechanical ventilation (1 hr each, Latin squares sequence): 1) PSV, 2) PSV combined with intermittent sighs (PSV + Sighs), 3) BIPAP/APRV + spontaneous breathing, and 4) noisy PSV with random variation of pressure support (normal distribution). The mean level of pressure support was set identical in all PSV forms. We found that noisy PSV increased tidal volume variability compared with PSV and PSV + Sighs (19% vs. 5% and 7%, respectively, p Conclusions: In the surfactant depletion model of acute lung injury, the new noisy PSV increased the variability of the respiratory pattern and improved oxygenation by a redistribution of perfusion toward the ventilated nondependent lung regions with simultaneous lower mean airway pressure, comparable minute ventilation, and no increase in the inspiratory effort or cardiac output.Keywords
This publication has 34 references indexed in Scilit:
- Airway Pressure Release and Biphasic Intermittent Positive Airway Pressure Ventilation: Are They Ready for Prime Time?Published by Wolters Kluwer Health ,2007
- Mechanical ventilation promotes redox status alterations in the diaphragmJournal of Applied Physiology, 2006
- Reduced breathing variability as a predictor of unsuccessful patient separation from mechanical ventilation*Critical Care Medicine, 2006
- Effects of partial ventilatory support modalities on respiratory function in severe hypoxemic lung injury*Critical Care Medicine, 2006
- Spontaneous breathing affects the spatial ventilation and perfusion distribution during mechanical ventilatory support*Critical Care Medicine, 2005
- Ventilator strategies for posttraumatic acute respiratory distress syndrome: airway pressure release ventilation and the role of spontaneous breathing in critically ill patientsCurrent Opinion in Critical Care, 2004
- Spontaneous Breathing Improves Lung Aeration in Oleic Acid–induced Lung InjuryAnesthesiology, 2003
- Pressure Support Compared with Controlled Mechanical Ventilation in Experimental Lung InjuryAnesthesia & Analgesia, 2002
- Variability of breath-by-breath tidal volume and its characteristics in normal and diseased subjects Ventilatory monitoring with electrical impedance pneumography.Japanese Journal of Medicine, 1985
- In Vivo Lung Lavage as an Experimental Model of the Respiratory Distress SyndromeActa Anaesthesiologica Scandinavica, 1980