Time Delay Compensation for Closed-Loop Insulin Delivery Systems: A Simulation Study
- 1 June 1991
- journal article
- research article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 14 (6) , 350-358
- https://doi.org/10.1177/039139889101400606
Abstract
Closed loop insulin therapy certainly represents the best possible approach to insulin replacement. However, present limitations preclude wider application of the so-called artificial pancreas. Therefore, a thorough understanding of these limitations is needed to design better systems for future long-term use. The present simulation study was designe: to obtain better information on the impact of the measurement delay of currently available closed-loop devices both during closed-loop insulin delivery and blood glucose clamp studies, and to design and test a time delay compensator based on the method originally described by O.J. Smith. Simulations were performed on a Compaq Deskpro 486/25™ personal computer under MS-DOS™ operating system using Simnon™ rel. 3.00 software. There was a direct relationship between measurement delay and amount of insulin delivered, i.e., the longer the delay the higher the insulin dose needed to control a rise in blood glucose; the closed-loop response in presence of a time delay was qualitatively impaired both during insulin delivery and blood glucose clamp studies; time delay compensation was effective in reducing the insulin dose and improving controller stability during the early phase of clamp studies. However, the robustness of a Smith's predictor-based controller should be carefully evaluated before implementation in closed-loop systems can be considered. 1) 1) Compaq Deskpro is a trademark of Compaq Computer Corporation; MS-DOS is a trademark of Microsoft Corporation; Simnon is a trademark of SSPA Systems.Keywords
This publication has 15 references indexed in Scilit:
- An Amperometric Needle‐type Glucose Sensor Tested in Rats and ManDiabetic Medicine, 1988
- Assessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogsDiabetologia, 1987
- Smith predictor and self-tuning control of muscle-relaxant drug administrationIEE Proceedings D Control Theory and Applications, 1985
- Improvement of Artificial Endocrine Pancreas (Biostator; GCIIS) Performance Combining Feedback Controlled Insulin Administration with a Pre-Programmed Insulin InfusionHormone and Metabolic Research, 1982
- Use of a Physiologic Pharmacokinetic Model of Glucose Homeostasis for Assessment of Performance Requirements for Improved Insulin TherapiesDiabetes Care, 1982
- Optimal feedback glycaemia regulation in diabeticsMedical & Biological Engineering & Computing, 1982
- An integrated mathematical model of the dynamics of blood glucose and its hormonal controlMathematical Biosciences, 1982
- Improvement of system performance by the use of time-delay elementsIEE Proceedings D Control Theory and Applications, 1982
- Control of Blood Sugar in Insulin-Dependent Diabetes: Comparison of an Artificial Endocrine Pancreas, Continuous Subcutaneous Insulin Infusion, and Intensified Conventional Insulin TherapyNew England Journal of Medicine, 1980
- Insulin Control of Glucose Metabolism in ManJournal of Clinical Investigation, 1975