A high pressure matrix‐assisted laser desorption/ionization Fourier transform mass spectrometry ion source for thermal stabilization of labile biomolecules
- 5 September 2001
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 15 (19) , 1862-1868
- https://doi.org/10.1002/rcm.447
Abstract
A high pressure matrix-assisted laser desorption/ionization (MALDI) Fourier transform mass spectrometry (FTMS) ion source was designed and tested. With this design, pressure is pulsed to an estimated 1–10 mbar in the region of the MALDI sample during desorption with the result of significantly decreased fragmentation compared to similar systems operating with pressures of <0.1 mbar. The thermal stabilization of vibrationally excited ions under these conditions is shown with small peptides desorbed from the ‘hot’ matrix α-cyano-4-hydroxycinnamic acid, and with the highly labile oxidized β-chain of insulin. Fragile gangliosides with several sialic acid residues are desorbed under high pressure and remain intact without the typical losses of sialic acid, and a protein standard, ubiquitin (8565.64 Da), is desorbed with minimal dehydration. Under high pressure collisional cooling conditions, non-covalent matrix adduction to the molecular ions becomes prominent, but with the trapped ions in an FT mass spectrometer, the ions can be mildly activated to detach the matrix adducts. The new source, additionally, generates significant levels of the multiply charged ions which are commonly seen in MALDI-TOFMS, but are rarely observed in MALDI-FTMS. This effect is more likely due to the elimination of a mass filtering effect in the previous FTMS ion source than to collisional cooling of the ions. Copyright © 2001 John Wiley & Sons, Ltd.Keywords
This publication has 47 references indexed in Scilit:
- Matrix-assisted ultraviolet laser desorption of non-volatile compoundsPublished by Elsevier ,2001
- Correction of Time-of-Flight Shifted Polymeric Molecular Weight Distributions in Matrix-Assisted Laser Desorption/Ionization Fourier Transform Mass SpectrometryAnalytical Chemistry, 1997
- Matrix-assisted Laser Desorption/Ionization Mass Spectrometry Sample Preparation Techniques Designed for Various Peptide and Protein AnalytesJournal of Mass Spectrometry, 1997
- Rapid microscale analyses with an external ion source Fourier transform ion cyclotron resonance mass spectrometerInternational Journal of Mass Spectrometry and Ion Processes, 1996
- A 4.7 Tesla internal MALDI-FTICR instrument for high mass studies: performance and methodsInternational Journal of Mass Spectrometry and Ion Processes, 1996
- Influence of the laser intensity and spot size on the desorption of molecules and ions in matrix-assisted laser desorption/ionization with a uniform beam profileInternational Journal of Mass Spectrometry and Ion Processes, 1995
- Elimination of axial ejection during excitation with a capacitively coupled open trapped-ion cell for Fourier transform ion cyclotron resonance mass spectrometryAnalytical Chemistry, 1992
- 2,5-Dihydroxybenzoic acid: a new matrix for laser desorption—ionization mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1991
- Sustained off-resonance irradiation for collision-activated dissociation involving Fourier transform mass spectrometry. Collision-activated dissociation technique that emulates infrared multiphoton dissociationAnalytica Chimica Acta, 1991
- UV laser matrix desorption/ionization mass spectrometry of proteins in the 100 000 dalton rangeInternational Journal of Mass Spectrometry and Ion Processes, 1989