Transient Thermal Response Measurements of Power Transistors

Abstract
Differences between the measured thermal impedance of power transistors when determined by the pulsed heating curve and cooling curve techniques are discussed. These differences are shown to result primarily because the power density distributions of these devices change as devicesheat; as a result of these changes the heating curve and the cooling curve are not conjugate. It is shown that the cooling curve technique, when the cooling curve is initiated from the most non-uniform steady-state thermal, distribution, (maximum voltage, maximum power) will indicate a larger value for the thermal impedance than will the pulsed heating curve technique, even for pulses in excess of the dc power level. A one-dimensional model for power transistor cooling is described. The theoretical predictions of the model are shown to be in good agreement for practical applications with three-dimensional computer simulations and experimental results. Using this model, it is possible to estimate an average junction temperature and the area of power generation at steady-state. Both TO-66 and TO-3 encased devices of mesa and planar structures were included in this study.

This publication has 5 references indexed in Scilit: