Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry
- 1 October 2002
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 47 (20) , 3629-3641
- https://doi.org/10.1088/0031-9155/47/20/305
Abstract
We have investigated the dependence of the measured optical density on the incident beam energy, field size and depth for a new type of film, Kodak extended dose range (Kodak EDR). Film measurements have been conducted over a range of field sizes (3 × 3 cm2 to 25 × 25 cm2) and depths (dmax to 15 cm), for 6 MV and 15 MV photons within a solid water phantom, and the variation in sensitometric response (net optical density versus dose) has been reported. Kodak EDR film is found to have a linear response with dose, from 0 to 350 cGy, which is much higher than that typically seen for Kodak XV film (0–50 cGy). The variation in sensitometric response for Kodak EDR film as a function of field size and depth is observed to be similar to that of Kodak XV film; the optical density varied in the order of 2–3% for field sizes of 3 × 3 cm2 and 10 × 10 cm2 at depths of dmax, 5 cm and 15 cm in the phantom. Measurements for a 25 × 25 cm2 field size showed consistently higher optical densities at depths of dmax, 5 cm and 15 cm, relative to a 10 × 10 cm2 field size at 5 cm depth, with 4–5% differences noted at a depth of 15 cm. Fractional depth dose and profiles conducted with Kodak EDR film showed good agreement (2%/2 mm) with ion chamber measurements for all field sizes except for the 25 × 25 cm2 at depths greater than 15 cm, where differences in the order of 3–5% were observed. In addition, Kodak EDR film measurements were found to be consistent with those of Kodak XV film for all fractional depth doses and profiles. The results of this study indicate that Kodak EDR film may be a useful tool for relative dosimetry at higher dose ranges.Keywords
This publication has 19 references indexed in Scilit:
- Variation of sensitometric curves of radiographic films in high energy photon beamsMedical Physics, 2001
- Use of CEA TVS film for measuring high energy photon beam dose distributionsMedical Physics, 1998
- Experimental determination of the convolution kernel for the study of the spatial response of a detectorMedical Physics, 1998
- The use of deconvolution and total least squares in recovering a radiation detector line spread functionMedical Physics, 1998
- A new approach to film dosimetry for high energy photon beams: Lateral scatter filteringMedical Physics, 1997
- Two-dimensional film dosimetry application in heterogeneous materials exposed to megavoltage photon beamsMedical Physics, 1997
- Dosimetry of high energy photon and electron beams with CEA filmsMedical Physics, 1996
- Calibration of Film for Accurate Megavoltage Photon DosimetryMedical Dosimetry, 1994
- A simple technique for film dosimetryRadiotherapy and Oncology, 1992
- Sensitometry of the response of a new radiochromic film dosimeter to gamma radiation and electron beamsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1991