The superiority of polymerase chain reaction over an amplified enzyme immunoassay for the detection of genital chlamydial infections
Open Access
- 1 February 2006
- journal article
- research article
- Published by BMJ in Sexually Transmitted Infections
- Vol. 82 (1) , 37-40
- https://doi.org/10.1136/sti.2005.015362
Abstract
Background/objectives: The polymer conjugate enhanced enzyme immunoassay (IDEIA) and Cobas Amplicor polymerase chain reaction Chlamydia trachomatis (CT) (Amplicor PCR) are two commonly used assays for the diagnosis of CT infection. The performance of these assays was compared for the diagnosis of genital CT infection among 1000 consecutive patients attending a genitourinary medicine (GUM) clinic. Confirmation of positive results and the clinical significance of the absence of cryptic plasmid in chlamydia on the diagnosis of infection by Amplicor PCR were also investigated. Methods: IDEIA, Amplicor PCR, and two nested in-house PCR assays targeting cryptic plasmid and omp1 gene were performed on all samples. DNA from Amplicor PCR negative samples was pooled for in-house PCR assays. Each pool contained DNA from seven Amplicor PCR negative samples. Results: Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and efficiency of IDEIA in the diagnosis of genital CT infection were 80%, 97%, 80%, 97%, and 95%, respectively. Sensitivity, specificity, PPV, NPV and efficiency of Amplicor PCR were 99%, 98%, 89%, 100%, and 98%, respectively. 16 (11%) of 144 Amplicor PCR positive results were identified as false positive by in-house PCR assays. No isolate of plasmid free CT was detected among the study population. Conclusions: IDEIA should not be used for the diagnosis of CT infection because of its poor sensitivity. Although the analytic specificity of Amplicor PCR was 98%, because of the adverse medical, social, and psychological impact of false positive results for patients, confirmation of Amplicor PCR positive results by a different assay with comparable sensitivity is essential. Amplification assays targeting cryptic plasmid are appropriate for the diagnosis of genital CT infections.Keywords
This publication has 9 references indexed in Scilit:
- Validation of Roche COBAS Amplicor Assay for Detection of Chlamydia trachomatis in Rectal and Pharyngeal Specimens by an omp1 PCR AssayJournal of Clinical Microbiology, 2004
- Chlamydia trachomatis diagnosticsSexually Transmitted Infections, 2002
- Comparison of a Polymer Conjugate-Enhanced Enzyme Immunoassay to Ligase Chain Reaction for Diagnosis of Chlamydia trachomatis in Endocervical SwabsJournal of Clinical Microbiology, 2001
- Evaluation of a new amplified enzyme immunoassay (EIA) for the detection ofChlamydia trachomatisin male urine, female endocervical swab, and patient obtained vaginal swab specimensJournal of Clinical Pathology, 2000
- Detection of Chlamydia trachomatis in vaginal specimens from female commercial sex workers using a new improved enzyme immunoassaySexually Transmitted Infections, 1998
- Clinical study of the effectiveness of a dual amplified immunoassay IDEIA PCE Chlamydia for the diagnosis of male urethritisInternational Journal of STD & AIDS, 1998
- Plasmid diversity in ChlamydiaMicrobiology, 1997
- Detection of Chlamydia trachomatis by ligase chain reaction compared with polymerase chain reaction and cell culture in urogenital specimens.Sexually Transmitted Infections, 1995
- The 7.5-kb plasmid present in Chlamydia trachomatis is not essential for the growth of this microorganismPlasmid, 1990