Experimental Analysis of Catheter-Manometer Systems In Vitro and In Vivo
Open Access
- 1 December 1989
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 71 (6) , 893-906
- https://doi.org/10.1097/00000542-198912000-00013
Abstract
The static and dynamic responses of two combinations of transducer amplifiers, pressure transducers, resonance elimination devices, extension tubing, and transcutaneous cannulae were tested in vitro using a sine-wave pressure generator, and in vivo by square-wave pressures generated by a "fast-flush" device. In addition, carotid arterial blood pressure waveforms recorded by these systems in sheep, at two different heart rates, were compared with those simultaneously recorded with a catheter-tip pressure transducer. A new term, "Working Heart Rate" is defined and allows for the prediction of the maximum heart rate up to which a system of given frequency response and damping coefficient should be accurate. When tested in vitro, all the monitoring systems were underdamped and resonated. The performance of all systems was improved by inclusion of an adjustable resonance elimination device but impaired by a nonadjustable resonance eliminator or by recording with an electronically filtered amplifer. When tested in vivo, the accuracy of mean and diastolic blood pressure measurement was not affected by any combination of heart rate, amplifier, length of extension tubing, or use of resonance eliminators. Both resonance elimination devices improved the performance of all systems. In contrast to predictions based on frequency response and damping, the smallest errors in systolic blood pressure were recorded using the electronic filter or the nonadjustable resonance eliminator. There were considerable and misleading differences between the frequency responses and damping coefficients calculated in vitro and those, for the same systems, derived from the in vivo fast-flush tests. It is concluded that the most accurate and consistent readings of systolic blood pressure will be achieved with the use of either an electronic filter or a nonadjustable resonance eliminator.This publication has 7 references indexed in Scilit:
- Accuracy and dynamic response of disposable pressure transducertubing systemsCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1987
- A SHEEP PREPARATION FOR STUDYING INTERACTIONS BETWEEN BLOOD FLOW AND DRUG DISPOSITION. I: PHYSIOLOGICAL PROFILEBritish Journal of Anaesthesia, 1984
- Direct Blood Pressure Measurement —Dynamic Response RequirementsAnesthesiology, 1981
- The Dynamic Responses of Liquid-filled Catheter Systems for Direct Measurements of Blood PressureAnesthesiology, 1980
- Determination of frequency response from step response: application to fluid-filled cathetersAmerican Journal of Physiology-Heart and Circulatory Physiology, 1979
- Physiologic Recording by Modern Instruments With Particular Reference to Pressure RecordingPhysiological Reviews, 1960
- Physical response requirements of pressure transducers for the reproduction of physiological phenomenaTransactions of the American Institute of Electrical Engineers, Part I: Communication and Electronics, 1956