Longitudinal Changes in Corneal Curvature in Keratoconus
- 1 April 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Cornea
- Vol. 25 (3) , 296-305
- https://doi.org/10.1097/01.ico.0000178728.57435.df
Abstract
Purpose: This study was designed to identify factors that predict longitudinal increases in corneal curvature as measured by the First Definite Apical Clearance Lens (FDACL) and flatter keratometric reading (Flat K) in keratoconus. Methods: The Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study is a long-te rm evaluation of the natural history of keratoconus involving 1209 patients. This report uses 8 years of follow-up data from 1032 patients who had penetrating keratoplasty in neither eye at baseline and who provided enough data to compute the slope of the change with time in the FDACL or the Flat K. Outcome measures included the aforementioned slopes and whether the FDACL or the Flat K increased by 3.00 or more diopters (D) in at least 1 eye. Results: At CLEK Study entry, patients were aged 38.9 ± 10.8 years. Overall, 44.3% of them were women, and 69.3% of them were white. The slope of the change in FDACL (0.18 ± 0.60 D/y) and Flat K (0.20 ± 0.80 D) during 8 years translates into expected 8-year increases of 1.44 D in FDACL and 1.60 D in Flat K. Increases of ≥3.00 D in either eye had an 8-year incidence of 24.8% for FDACL and 24.1% for Flat K. Independent predictors of increased FDACL included younger age, poorer baseline high-contrast manifest refraction visual acuity, and non-white race. Younger age and poorer high-contrast manifest refraction visual acuity were independent predictors of a >3.00-D increase for both FDACL and Flat K. Conclusion: CLEK patients exhibited a slow but clear increase in corneal curvature. Younger age and poorer high-contrast manifest refraction visual acuity at baseline predicted the rate of change in corneal curvature.Keywords
This publication has 15 references indexed in Scilit:
- Accuracy and Precision of EyeSys and Orbscan Systems on Calibrated Spherical Test SurfacesEye & Contact Lens: Science & Clinical Practice, 2004
- Impact of Preoperative Corneal Curvature on the Outcome of Penetrating Keratoplasty in KeratoconusCornea, 2003
- Between-Eye Asymmetry in KeratoconusCornea, 2002
- Comparison of Repeat Videokeratography: Repeatability and AccuracyOptometry and Vision Science, 1998
- Repeatability and Agreement of Two Corneal-Curvature Assessments in KeratoconusCornea, 1998
- Short- and Long-Term Repeatability of Visioptic Alcon EyeMap (Visioptic EH-270) Corneal Topographer on Normal Human CorneasOptometry and Vision Science, 1995
- Comparison of the accuracy and reproducibility of the keratometer and the EyeSys Corneal Analysis System Model IJournal of Cataract & Refractive Surgery, 1992
- Reproducibility of Normal Corneal Power Measurements With a Keratometer, Photokeratoscope, and Video Imaging SystemArchives of Ophthalmology (1950), 1990
- RELIABILITY OF KERATOMETRIC READINGSOptometry and Vision Science, 1969
- Le kératocône fruste au JavalOphthalmologica, 1938