AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiology
Top Cited Papers
Open Access
- 12 June 2001
- journal article
- guideline
- Published by Wiley in Medical Physics
- Vol. 28 (6) , 868-893
- https://doi.org/10.1118/1.1374247
Abstract
The American Association of Physicists in Medicine (AAPM) presents a new protocol, developed by the Radiation Therapy Committee Task Group 61, for reference dosimetry of low‐ and medium‐energy x rays for radiotherapy and radiobiology It is based on ionization chambers calibrated in air in terms of air kerma. If the point of interest is at or close to the surface, one unified approach over the entire energy range shall be used to determine absorbed dose to water at the surface of a water phantom based on an in‐air measurement (the “in‐air” method). If the point of interest is at a depth, an in‐water measurement at a depth of 2 cm shall be used for tube potentials ⩾100 kV (the “in‐phantom” method). The in‐phantom method is not recommended for tube potentials <100 kV. Guidelines are provided to determine the dose at other points in water and the dose at the surface of other biological materials of interest. The protocol is based on an up‐to‐date data set of basic dosimetry parameters, which produce consistent dose values for the two methods recommended. Estimates of uncertainties on the final dose values are also presented.Keywords
This publication has 52 references indexed in Scilit:
- Photon mass attenuation and energy-absorption coefficientsPublished by Elsevier ,2002
- Forward dose perturbation at high atomic number interfaces in kilovoltage x-ray beamsMedical Physics, 1997
- The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al - 4 mm Cu HVL; 10 - 300 kV generating potential)Physics in Medicine & Biology, 1996
- Performance characteristics of the Pantak DXT-300 kilovoltage X-ray treatment machineThe British Journal of Radiology, 1996
- Beam characteristics of the Therapax DXT300 orthovoltage therapy unitPhysics in Medicine & Biology, 1994
- Correction factors for a cylindrical ionization chamber used in medium-energy X-ray beamsPhysics in Medicine & Biology, 1993
- Contamination of ionization chambers by talcum powderMedical Physics, 1988
- Dosimetric Precision Requirements in Radiation TherapyActa Radiologica: Oncology, 1984
- Use of a Victoreen 500 electrometer to determine ionization chamber collection efficienciesMedical Physics, 1981