Three direct spectrophotometric methods for determination of total bilirubin in neonatal and adult serum, adapted to the Technicon RA-1000 analyzer.
Open Access
- 1 September 1989
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 35 (9) , 1980-1986
- https://doi.org/10.1093/clinchem/35.9.1980
Abstract
We adapted three bichromatic spectrophotometric methods for determining total bilirubin in serum, for use with the Technicon RA-1000 analyzer. The borate buffer (BOR) of Hertz et al. (Scand J Clin Invest 1974;33:215-30), the caffeine buffer (CAF) of Vink et al. (Clin Chem 1988;34:67-70), and the combined borate-caffeine buffer (B-C) of Franzini and Cattozzo (Clin Chem 1987;33:597-9) were compared. All methods required only 10 microL of serum, were precise (between-batch CVs less than 4.2%, analyte range 64-310 mumol/L), linear to 1000 mumol/L, and insensitive to interference from hemoglobin to 5 g/L. Lipemia, carotene, and methemalbumin interfered positively with each method but insignificantly unless in supranormal concentrations. Only the BOR method was sensitive to protein matrix effect. Neonates' results obtained with all three methods compared well with a Jendrassik-Gróf-based technique. However, samples from adults with cholestasis were overestimated, particularly by the CAF method, but the BOR and B-C methods would be suitable for "stat" bilirubin analysis in these samples.This publication has 12 references indexed in Scilit:
- Delta bilirubin: absorption spectra, molar absorptivity, and reactivity in the diazo reaction.Clinical Chemistry, 1987
- Caffeine-splitting of bilirubin/albumin complex: its relevance to the spectrophotometry of bilirubin in serum.Clinical Chemistry, 1987
- Reflections on the Standardization of Total Bilirubin in Neonatal Serumcclm, 1987
- Use of the caffeine reagent in direct spectrophotometry of bilirubin.Clinical Chemistry, 1986
- Measurement of total bilirubin by use of bilirubin oxidase.Clinical Chemistry, 1986
- Determination of serum methemalbumin by second-derivative spectroscopyClinica Chimica Acta; International Journal of Clinical Chemistry, 1982
- Determination of Total and Direct Bilirubin in Plasma by Means of a Bichromatic Method on a Centrifugal AnalyserAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1982
- Isolation and preliminary characterization of a fraction of bilirubin in serum that is firmly bound to protein.Clinical Chemistry, 1982
- Jendrassik--Grof analysis for total and direct bilirubin in serum with a centrifugal analyzer.Clinical Chemistry, 1981
- A Survey Report on the Determination of Total Bilirubin in Neonatal Samples.cclm, 1980