Multiplexed MS/MS in a Quadrupole Ion Trap Mass Spectrometer
- 18 November 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (24) , 7346-7353
- https://doi.org/10.1021/ac048955d
Abstract
A multiplexing method for performing MS/MS on multiple peptide ions simultaneously in a quadrupole ion trap mass spectrometer (QITMS) has been developed. This method takes advantage of the inherent mass bias associated with ion accumulation in the QITMS to encode the intensity of precursor ions in a way that allows the corresponding product ions to be identified. The intensity encoding scheme utilizes the Gaussian distributions that characterize the relationship between ion intensities and rf trapping voltages during ion accumulation. This straightforward approach uses only two arbitrary waveforms, one for isolation and one for dissociation, to gather product ion spectra from N precursor ions in as little as two product ion spectra. In the example used to illustrate this method, 66% of the product ions from five different precursor peptide ions were correctly correlated using the multiplexing approach. Of the remaining 34% of the product ions, only 6% were misidentified, while 28% of the product ions failed to be identified because either they had too low intensity or they had the same m/z ratio as one of the precursor ions or the same m/z ratio as a product ion from a different precursor ion. This method has the potential to increase sample throughput, reduce total analysis times, and increase signal-to-noise ratios as compared to conventional MS/MS methods.Keywords
This publication has 26 references indexed in Scilit:
- Impact of Ion Trap Tandem Mass Spectra Variability on the Identification of PeptidesAnalytical Chemistry, 2004
- Low-Attomole Electrospray Ionization MS and MS/MS Analysis of Protein Tryptic Digests Using 20-μm-i.d. Polystyrene−Divinylbenzene Monolithic Capillary ColumnsAnalytical Chemistry, 2003
- Tandem Mass Tags: A Novel Quantification Strategy for Comparative Analysis of Complex Protein Mixtures by MS/MSAnalytical Chemistry, 2003
- Pulsed Gas Introduction for Increasing Peptide CID Efficiency in a MALDI/Quadrupole Ion Trap Mass SpectrometerAnalytical Chemistry, 1996
- Tutorial review. Future prospects for the analysis of complex biological systems using micro-column liquid chromatography–electrospray tandem mass spectrometryThe Analyst, 1996
- Use of Infrared Multiphoton Photodissociation with SWIFT for Electrospray Ionization and Laser Desorption Applications in a Quadrupole Ion Trap Mass SpectrometerAnalytical Chemistry, 1996
- Interlaboratory comparison of different analytical techniques for the determination of oxygen-18 abundanceAnalytical Chemistry, 1990
- Coupling of an atmospheric-samling ion source with an ion-trap mass spectrometerAnalytica Chimica Acta, 1989
- Injection of ions into a quadrupole ion trap mass spectrometerInternational Journal of Mass Spectrometry and Ion Processes, 1989
- Unusual spectroscopic features in the emission and absorption spectra of single-crystal potassium tetrachloroplatinate(II) (K2[PtCl4]) caused by multiple-mode excited-state distortionsJournal of the American Chemical Society, 1988