Fast phase‐contrast velocity measurement in the steady state
Open Access
- 1 November 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (5) , 890-898
- https://doi.org/10.1002/mrm.10285
Abstract
A new method of encoding flow velocity as image phase in a refocused steady-state free precession (SSFP) sequence, called steady-state phase contrast (SSPC), can be used to generate velocity images rapidly while retaining high signal. Magnitude images with refocused-SSFP contrast are simultaneously acquired. This technique is compared with the standard method of RF-spoiled phase contrast (PC), and is found to have more than double the phase-signal to phase-noise ratio (PNR) when compared with standard PC at reasonable repetition intervals (TRs). As TR decreases, this advantage increases exponentially, facilitating rapid scans with high PNR efficiency. Rapid switching between the two necessary steady states can be accomplished by the insertion of a single TR interval with no flow-encoding gradient. The technique is implemented in a 2DFT sequence and validated in a phantom study. Preliminary results indicate that further TR reduction may be necessary for high-quality cardiac images; however, images in more stationary structures, such as the descending aorta and carotid bifurcation, exhibit good signal-to-noise ratio (SNR) and PNR. Comparisons with standard-PC images verify the PNR advantage predicted by theory. Magn Reson Med 48:890–898, 2002.Keywords
This publication has 27 references indexed in Scilit:
- Magnetic resonance velocity imaging using a fast spiral phase contrast sequenceMagnetic Resonance in Medicine, 1994
- Interleaved echo planar flow quantitationMagnetic Resonance in Medicine, 1994
- Comparison of phase‐difference and complex‐difference processing in phase‐contrast MR angiographyJournal of Magnetic Resonance Imaging, 1991
- Encoding strategies for three‐direction phase‐contrast MR imaging of flowJournal of Magnetic Resonance Imaging, 1991
- Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm (NMR imaging)IEEE Transactions on Medical Imaging, 1991
- Motion‐insensitive, steady‐state free precession imagingMagnetic Resonance in Medicine, 1990
- Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradients in NMR systemsJournal of Magnetic Resonance (1969), 1990
- An analysis of fast imaging sequences with steady‐state transverse magnetization refocusingMagnetic Resonance in Medicine, 1988
- Phase and intensity anomalies in fourier transform NMRJournal of Magnetic Resonance (1969), 1971