Multi–Detector Row CT Systems and Image-Reconstruction Techniques
Top Cited Papers
- 1 June 2005
- journal article
- review article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 235 (3) , 756-773
- https://doi.org/10.1148/radiol.2353040037
Abstract
The introduction in 1998 of multi-detector row computed tomography (CT) by the major CT vendors was a milestone with regard to increased scan speed, improved z-axis spatial resolution, and better utilization of the available x-ray power. In this review, the general technical principles of multi-detector row CT are reviewed as they apply to the established four- and eight-section systems, the most recent 16-section scanners, and future generations of multi-detector row CT systems. Clinical examples are used to demonstrate both the potential and the limitations of the different scanner types. When necessary, standard single-section CT is referred to as a common basis and starting point for further developments. Another focus is the increasingly important topic of patient radiation exposure, successful dose management, and strategies for dose reduction. Finally, the evolutionary steps from traditional single-section spiral image-reconstruction algorithms to the most recent approaches toward multisection spiral reconstruction are traced.Keywords
This publication has 83 references indexed in Scilit:
- CT-Angiographie der A. carotis: Erste Erfahrungen mit einem 16-Schicht-Spiral-CTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- New technical developments in multislice CT - Part 1: Approaching isotropic resolution withsub-millimeter 16-slice scanning -RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Imaging of aortic prosthesis infection with a combined SPET/CT deviceEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- Multislice Helical CT of Focal and Diffuse Lung DiseaseAmerican Journal of Roentgenology, 2001
- ECG‐correlated image reconstruction from subsecond multi‐slice spiral CT scans of the heartMedical Physics, 2000
- High temporal resolution for multislice helical computed tomographyMedical Physics, 2000
- Efficient correction for CT image artifacts caused by objects extending outside the scan field of viewMedical Physics, 2000
- Spiral interpolation algorithms for multislice spiral CT. II. Measurement and evaluation of slice sensitivity profiles and noise at a clinical multislice systemIEEE Transactions on Medical Imaging, 2000
- Single-slice rebinning reconstruction in spiral cone-beam computed tomographyIEEE Transactions on Medical Imaging, 2000
- A general cone-beam reconstruction algorithmIEEE Transactions on Medical Imaging, 1993