Increasing Quantitation Accuracy of Fluorescent Excitation Analysis (Fea) Systems by Pulse Rise-Time Discrimination
- 1 January 1981
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 28 (1) , 123-126
- https://doi.org/10.1109/tns.1981.4331152
Abstract
The quantitation accuracy of FEA systems is dependent on the characteristic x-ray to background ratio. This background appears as a continuum of energy lower than the primary Compton scatter peak (PCSP) from the sample being assayed. In a well designed FEA system most of this low energy background does not arise from multiple Compton scatter in the sample or collimators. Rather, it results from interaction between the PCSP and the Si(Li) detector system. Although guard-ring anticoincidence or narrow collimation help to reduce background, in a good detector edge field effects play a small role, and background appears to be a volume effect. Polarized FEA has been shown to improve quantitation by reducing the PCSP to characteristic x-ray ratio, but the basic detector problem remains. We describe a pulse risetime discrimination scheme whereby slow pulses arising in the detector are discarded. For FEA of iodine with Am-241, this addition to the system produces a halving of background with a minimal impact (1-3% loss) on count-rate of iodine K x-rays. Similar results are obtained for FEA of bromine with Cd-109.Keywords
This publication has 9 references indexed in Scilit:
- An evaluation of HgI2 detectors for x-ray computed tomographyMedical Physics, 1980
- An Evaluation of Cadmium Telluride Detectors for Computer Assisted TomographyJournal of Computer Assisted Tomography, 1978
- Fluorescent excitation analysis in medicineJournal of Radioanalytical and Nuclear Chemistry, 1978
- A novel pulse processing system for HgI2 detectorsNuclear Instruments and Methods, 1978
- XRF analysis - some sensitivity comparisons between charged-particle and photon excitationNuclear Instruments and Methods, 1977
- The use of cadmium telluride γ spectrometers in monitoring activity deposited in nuclear power stationsRevue de Physique Appliquée, 1977
- A High Intensity Source of Polarized X-Rays for Fluorescent Excitation Analysis (FEA)IEEE Transactions on Nuclear Science, 1977
- An Automated Fluorescent Excitation Analysis System for Medical ApplicationsInvestigative Radiology, 1976
- Some Applications of Si(Li) Detectors to Clinical ProblemsIEEE Transactions on Nuclear Science, 1973