Epithermal Neutron Beam Design for Neutron Capture Therapy at the Power Burst Facility and the Brookhaven Medical Research Reactor
- 1 October 1990
- journal article
- research article
- Published by Taylor & Francis in Nuclear Technology
- Vol. 92 (1) , 106-117
- https://doi.org/10.13182/nt90-a34490
Abstract
Nuclear design studies have been performed for two reactor-based epithermal neutron beams for cancer treatment by neutron capture therapy (NCT). An intermediate-intensity epithermal beam has been designed and implemented at the Brookhaven Medical Research Reactor (BMRR). Measurements show that the BMRR design predictions for the principal characteristics of this beam are accurate. A canine program for research into the biological effects of NCT is now under way at BMRR. The design for a high-intensity epithermal beam with minimal contamination from undesirable radiation components has been finalized for the Power Burst Facility (PBF) at the Idaho National Engineering Laboratory. This design will be implemented when it is determined that human NCT trials are advisable. The PBF beam will exhibit approximately an order of magnitude improvement in absolute epithermal flux intensity over that available in the BMRR, and its angular distribution and spectral characteristics will be more advantageous for NCT. The combined effects of beam intensity, angular distribution, spectrum, and contaminant level allow the desired tumor radiation dose to be delivered in much shorter times than are possible with the currently available BMRR beam, with a significant reduction (factor of 3 to 5) in collateral dose due to beam contaminants.Keywords
This publication has 6 references indexed in Scilit:
- Conceptual Design of a Medical Reactor for Neutron Capture TherapyNuclear Technology, 1990
- Updated version of the DOT 4 one- and two-dimensional neutron/photon transport codePublished by Office of Scientific and Technical Information (OSTI) ,1982
- A Design Study of the Neutron Irradiation Facility for Boron Neutron Capture TherapyNuclear Technology, 1981
- Generation of a computer library for discrete ordinates quadrature sets. [DOQDP]Published by Office of Scientific and Technical Information (OSTI) ,1977
- Development and Dosimetry of an `Epithermal' Neutron Beam for Possible Use in Neutron Capture Therapy I. `Epithermal' Neutron Beam DevelopmentPhysics in Medicine & Biology, 1965
- TOPIC--A FORTRAN PROGRAM FOR CALCULATING TRANSPORT OF PARTICLES IN CYLINDERSPublished by Office of Scientific and Technical Information (OSTI) ,1964