Preliminary Results of Uncemented Metal on Metal Stemmed and Resurfacing Hip Replacement Arthroplasty
- 1 August 1996
- journal article
- Published by Wolters Kluwer Health
- Vol. 329, S78-S88
- https://doi.org/10.1097/00003086-199608001-00008
Abstract
Seventy uncemented stemmed total hip replacements and 35 uncemented surface replacements with all metal Metasul articulating surfaces were followed up in a prospective study. There was no evidence that this metal on metal articulation causes new problems or complications that were not known already from other polyethylene-aluminum oxide ceramic articulating combinations. The results of 64 of 70 patients could be assessed as excellent and good. When tissue samples obtained during 2 reoperations for ectopic ossification were examined histologically, there was no light microscopic evidence of metal particles. In these cases, aseptic loosening seemed to be due to the lack of initial fixation with the original femoral component design, and was not related to the use of the Metasul bearing. The metal on metal articulation reduces the production of particles considerably according to experience to date. It is therefore hoped that foreign body reactions due to wear particles will be significantly reduced. The results support the continued investigation of metal on metal joint replacements for younger, active patients.Keywords
This publication has 11 references indexed in Scilit:
- In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy couplingJournal of Biomedical Materials Research, 1993
- Studies of the mechanism by which the mechanical failure of polymethylmethacrylate leads to bone resorption.Journal of Bone and Joint Surgery, 1993
- Femur-RevisionsprotheseZeitschrift für Orthopädie und ihre Grenzgebiete, 1993
- Titanium wear debris in failed cemented total hip arthroplasty: An analysis of 71 casesThe Journal of Arthroplasty, 1992
- Gelenkprothesen-Komponenten aus warmgeschmiedeter und oberflächenbehandelter Ti-6Al-7Nb-Legierung - Joint Replacement Components Made of Hot-Forged and Surface-Treated Ti-6Al-7Nb AlloyBiomedizinische Technik/Biomedical Engineering, 1991
- Long-term results after implantation of McKee-Farrar total hip prosthesesArchives of orthopaedic and trauma surgery, 1991
- Friction and wear properties of polymer, metal, and ceramic prosthetic joint materials evaluated on a multichannel screening deviceJournal of Biomedical Materials Research, 1981
- Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in ManActa Orthopaedica, 1981
- Traumatic Arthritis of the Hip after Dislocation and Acetabular FracturesJournal of Bone and Joint Surgery, 1969
- REPLACEMENT OF ARTHRITIC HIPS BY THE McKEE-FARRAR PROSTHESISThe Journal of Bone and Joint Surgery. British volume, 1966