Rectilinear Ion Trap: Concepts, Calculations, and Analytical Performance of a New Mass Analyzer
Top Cited Papers
- 16 July 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (16) , 4595-4605
- https://doi.org/10.1021/ac049420n
Abstract
A mass analyzer based on a rectilinear geometry ion trap (RIT) has been built, and its performance has been characterized. Design concepts for this type of ion trap are delineated with emphasis on the effects of electrode geometry on the calculated electric field. The Mathieu stability region was mapped experimentally. The instrument can be operated using mass-selective instability scans in both the boundary and resonance ejection versions. Comparisons of performance between different versions of the device having different dimensions allowed selection of an optimized geometry with an appropriate distribution of higher-order electric fields. Comparisons made under the same conditions between the performance of a conventional cylindrical ion trap and a RIT of 4 times greater volume show an improvement of 40 times in the signal-to-noise ratio resulting from the higher ion trapping capacity of the RIT. The demonstrated capabilities of the RIT include tandem mass spectrometry, a mass resolution in excess of 1000, and a mass/charge range of 650 Th, all in a simple structure that is only 3.5 cm3 in internal volume.Keywords
This publication has 28 references indexed in Scilit:
- Performance of a multiplexed chemical ionization miniature cylindrical ion trap array mass spectrometerThe Analyst, 2004
- Characterization of a serial array of miniature cylindrical ion trap mass analyzersRapid Communications in Mass Spectrometry, 1999
- Chemical Mass Shifts in Ion Trap Mass Spectrometry: Experiments and SimulationsAnalytical Chemistry, 1999
- A Quadrupole Ion Trap with Cylindrical Geometry Operated in the Mass-Selective Instability ModeAnalytical Chemistry, 1998
- Miniature, high-resolution, quadrupole mass-spectrometer arrayReview of Scientific Instruments, 1997
- High-pressure effects in miniature arrays of quadrupole analyzers for residual gas analysis from 10−9 to 10−2 TorrJournal of Vacuum Science & Technology A, 1996
- High mass‐resolution using a quadrupole ion‐trap mass spectrometerRapid Communications in Mass Spectrometry, 1991
- Operation of a quadrupole ion trap mass spectrometer to achieve high mass/charge ratiosInternational Journal of Mass Spectrometry and Ion Processes, 1991
- Ion-trapping technique for ion/molecule reaction studies in the center quadrupole of a triple quadrupole mass spectrometerInternational Journal of Mass Spectrometry and Ion Processes, 1988
- Recent improvements in and analytical applications of advanced ion trap technologyInternational Journal of Mass Spectrometry and Ion Processes, 1984