Deep venous thrombosis evaluation with limited-flip-angle, gradient-refocused MR imaging: preliminary experience.
- 1 February 1988
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 166 (2) , 371-375
- https://doi.org/10.1148/radiology.166.2.3336713
Abstract
Sixteen patients (17 lower extremities) were prospectively examined with venography and limited-flip-angle, gradient-refocused magnetic resonance (MR) imaging for the presence or absence of deep venous thrombosis. Thrombosed vessels showed decreased-to-absent signal intensity, while patent vessels had high signal intensity. In 16 of 17 extremities, MR images allowed accurate detection and localization of the thrombi found with venography. In the remaining extremity, MR imaging allowed correct identification of thrombus in the iliac and femoral veins but incorrectly demonstrated clot in the calf and popliteal veins. MR imaging with limited-flip-angle, gradient-refocused pulse sequences appears to be a sensitive, noninvasive means of detecting deep venous thrombosis.This publication has 17 references indexed in Scilit:
- Abdominal venous system: assessment using MR.Radiology, 1985
- MR Imaging of Portal Vein Thrombus in Hepatocellular CarcinomaJournal of Computer Assisted Tomography, 1985
- Blood flow: magnetic resonance imaging.Radiology, 1985
- Diagnostic Efficacy of Impedance Plethysmography for Clinically Suspected Deep-Vein ThrombosisAnnals of Internal Medicine, 1985
- The appearance of rapidly flowing blood on magnetic resonance imagesAmerican Journal of Roentgenology, 1984
- NMR Even Echo Rephasing in Slow Laminar FlowJournal of Computer Assisted Tomography, 1984
- Impact of venography on the diagnosis and management of deep vein thrombosis.BMJ, 1983
- Nuclear Magnetic Resonance (NMR) In Vivo StudiesJournal of Computer Assisted Tomography, 1981
- The limited utility of fibrinogen I 125 leg scanningArchives of internal medicine (1960), 1979
- PULMONARY-EMBOLISMPublished by Elsevier ,1977