Abdominal MR angiography performed using blood pool contrast agents: comparison of a new superparamagnetic iron oxide nanoparticle and a linear gadolinium polymer.

Abstract
We evaluated and compared two different experimental blood pool contrast agents for abdominal MR angiography in an animal model.In seven pigs, coronal T1-weighted three-dimensional fast field-echo images were obtained on a conventional 1.5-T MR imaging system before and after i.v. injection of the ultrasmall superparamagnetic iron oxide agent FeO-BPA. In another seven pigs, MR angiograms were acquired using the gadolinium polymer WIN 22181. Enhanced images were obtained 5-210 min after injection of FeO-BPA and 1-120 min after injection of WIN 22181.Both blood pool agents yielded detailed angiograms of the abdominal vascular tree when imaging lasted 2 min. In-plane running vessels were imaged without saturation effects and with equivalent maximum signal-to-noise ratios. Half the maximum signal-to-noise ratio was reached 150 min after injection of FeO-BPA, whereas this interval was approximately 70 min for the gadolinium polymer. Because of these different imaging half-life periods, the effective diagnostic...