Bone Transport Using Intramedullary Fixation and a Single Flexible Traction Cable
- 1 April 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 325 (325) , 256-268
- https://doi.org/10.1097/00003086-199604000-00032
Abstract
The transfixing wires used in the limb-lengthening and bone-transport procedures described by Ilizarov are the primary source of complications, including infection, restricted joint motion, and pain. In an attempt to eliminate the need for external fixation, a traction cable device was devised to perform a 3-cm bone transport in the canine femur using an interlocking intramedullary rod for fixation. Twelve dogs were divided into 2 groups. Transport began 7 days after osteotomy and continued at either 1 mm per day (n = 6) or 2 mm per day (n = 6). The in vivo peak force, resting force, and stiffness of the transport segment increased throughout distraction to a mean of 150 Newtons, 58 N, and 58 N per millimeter, respectively, at the time of docking. The regenerate and docking sites united in 10 of 12 dogs. Failure of the regenerate associated with deep infection around the rod occurred in 2 animals (17%). Modifications of this technique to reduce the risk of infection are discussed. This study confirms that intramedullary fixation is compatible with distraction osteogenesis and shows that a single traction cable can provide the force necessary for bone transport without transfixing wires in this setting.Keywords
This publication has 18 references indexed in Scilit:
- Femoral Forces During Limb Lengthening in ChildrenClinical Orthopaedics and Related Research, 1994
- Major long-term complications in 1,422 permanent venous access devicesThe American Journal of Surgery, 1993
- Sonographic evaluation of bone production at the distraction site in Ilizarov limb-lengthening procedures.American Journal of Roentgenology, 1990
- Biomechanical measurement of fracture healingJournal of Medical Engineering & Technology, 1990
- Design of a Load Cell for the Wagner DistractorProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1989
- Local Bone Transportation for Treatment of Intercalary Defects by the Ilizarov TechniqueClinical Orthopaedics and Related Research, 1989
- The Tension-Stress Effect on the Genesis and Growth of TissuesClinical Orthopaedics and Related Research, 1989
- Bone lengthening in rabbits by callus distraction. The role of periosteum and endosteumThe Journal of Bone and Joint Surgery. British volume, 1988
- Rigidity and stress analyses of external fracture fixation devices—A theoretical approachJournal of Biomechanics, 1982
- Kontinuierliche Verlängerung des Femur bei intramedullärer StabilisierungArchives of orthopaedic and trauma surgery, 1975