Continuous Subcutaneous Glucose Monitoring in Diabetic Patients
Open Access
- 1 February 2002
- journal article
- research article
- Published by American Diabetes Association in Diabetes Care
- Vol. 25 (2) , 347-352
- https://doi.org/10.2337/diacare.25.2.347
Abstract
OBJECTIVE—To evaluate the accuracy of a new subcutaneous glucose sensor (Glucoday; A. Menarini Diagnostics) compared with venous blood glucose measurement in type 1 and type 2 diabetic patients. RESEARCH DESIGN—A multicenter study was performed in 70 diabetic patients. A microdialysis fiber was inserted subcutaneously into the periumbelical region and perfused with a buffer solution. Glucose concentrations in the dialysate were then measured every 3 min by the glucose sensor over a 24-h period, during which nine venous blood samples were also collected throughout the day. RESULTS—Both the insertion of the fiber and the wearing of the device were well tolerated by the patients. Subcutaneous glucose levels were well correlated with venous glucose measurements (r = 0.9, P < 0.001) over a wide range (40–400 mg/dl) for up to 24 h, with a single-point calibration. An analysis of 381 data pairs showed a linear relationship between the GlucoDay and serial venous blood glucose levels, and 97% of the data fell in the A and B regions of the error grid analysis. Percentage bias between the GlucoDay and the blood venous levels was −2.0% in the hypoglycemic range (180 mg/dl). CONCLUSIONS—The GlucoDay system demonstrated high reliability and reported values that closely agreed with venous blood glucose measurements. The system was well tolerated and thus constitutes a relatively easy method to monitor glucose excursions in diabetic patients.Keywords
This publication has 14 references indexed in Scilit:
- Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoringAmerican Journal of Physiology-Endocrinology and Metabolism, 2000
- Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoringAmerican Journal of Physiology-Endocrinology and Metabolism, 1999
- Lactate and Glycerol Release from Subcutaneous Adipose Tissue in Black and White Lean MenJournal of Clinical Endocrinology & Metabolism, 1999
- Microdialysis of Glucose in Subcutaneous Adipose Tissue up to 3 Weeks in Healthy VolunteersDiabetes Care, 1998
- United Kingdom Prospective Diabetes Study 24: A 6-Year, Randomized, Controlled Trial Comparing Sulfonylurea, Insulin, and Metformin Therapy in Patients with Newly Diagnosed Type 2 Diabetes That Could Not Be Controlled with Diet TherapyAnnals of Internal Medicine, 1998
- Open-Flow Microperfusion of Subcutaneous Adipose Tissue for On-Line Continuous Ex Vivo Measurement of Glucose ConcentrationDiabetes Care, 1997
- Self-Monitoring of Blood Glucose in Type I Diabetic Patients: Comparison With Continuous Microdialysis Measurements of Glucose in Subcutaneous Adipose Tissue During Ordinary Life ConditionsDiabetes Care, 1997
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- On line continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysisDiabetologia, 1992
- Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood GlucoseDiabetes Care, 1987