Tri-state myoelectric control of bilateral upper extremity neuroprostheses for tetraplegic individuals
- 1 December 1996
- journal article
- review article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Rehabilitation Engineering
- Vol. 4 (4) , 251-263
- https://doi.org/10.1109/86.547925
Abstract
For the purpose of bimanual control of tetraplegic hands that have useful movement restored by a neuroprosthetic device, the use of myoelectric signals from bilateral sternoclei-domastoid muscles is proposed. Three state control has been proposed where each sternocleidomastoid controls its ipsilateral hand. Demonstration was made with spinal-cord-injured and nonspinal-cord-injured subjects providing three levels of activation that can be repeatably made with each of these muscles. The agonist and antagonist sternocleidomastoids during this command control were differentiated so that the desired hand will respond to a command. Neither normal head movements nor head position within its comfortable range of motion were shown to interfere with the proposed command. The provision of feedback was shown as important to provide robustness in the operation for the users selection of the right or left hand. The performance of spinal cord injured and noninjured persons using this controller was quantitatively measured through the completion of precision tracking tasks by the manipulation of on-screen virtual hands. All subjects were able to operate the controller with a degree of skill acceptable for completion of functional tasks with bilateral stimulated hand grasps. The sensitivity of the subjects performance to variation in controller parameters was also measured.Keywords
This publication has 14 references indexed in Scilit:
- Tri-state myoelectric control of bilateral upper extremity neuroprostheses for tetraplegic individualsIEEE Transactions on Rehabilitation Engineering, 1996
- A myoelectric control evaluation and trainer systemIEEE Transactions on Rehabilitation Engineering, 1994
- Development of a quantitative hand grasp and release test for patients with tetraplegia using a hand neuroprosthesisThe Journal of Hand Surgery, 1994
- Grasp synthesis for upper-extremity FNSMedical & Biological Engineering & Computing, 1993
- Operator error in a level coded myoelectric control channelIEEE Transactions on Biomedical Engineering, 1993
- The application of a modified neuroprosthetic hand system in a child with a C7 spinal cord injury. Case reportSpinal Cord, 1992
- Sensory Feedback for Enhancing Upper Extremity Neuromuscular ProsthesesNeurorehabilitation and Neural Repair, 1991
- Evaluation of shoulder movement as a command control sourceIEEE Transactions on Biomedical Engineering, 1990
- The integrated roles of longus colli and sternocleidomastoid muscles: An electromyographic studyThe Anatomical Record, 1973
- Electromyographic studies on reflex activity of the intercostal and abdominal muscles in cervical cord lesionsSpinal Cord, 1965