Mercury Detection by Means of Thin Gold Films
- 10 November 1972
- journal article
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 178 (4061) , 611-612
- https://doi.org/10.1126/science.178.4061.611
Abstract
The adsorption of elemental mercury vapor on a thin (several hundred angstroms) gold film produces resistance changes in the film. An instrument for the detection of mercury based on this phenomenon is simple and rapid and requires no chemical separations other than passage of the vapor sample through a few standard dry filters. The instrument is portable, and the technique is directly applicable to environmental problems and geochemical prospecting. The limit of detection of the prototype instrument is 0.05 nanogram of mercury.Keywords
This publication has 11 references indexed in Scilit:
- Backscattering investigation of low-temperature migration of chromium through gold filmsApplied Physics Letters, 1972
- Hyperfine Zeeman Effect Atomic Absorption Spectrometer for MercuryScience, 1971
- The Determination of Mercury in Small Terrestrial and Nonterrestrial Rock Samples by Atomic-Absorption Spectroscopy, and the Study of Mercury Release at Elevated TemperaturesApplied Spectroscopy, 1971
- Size effects in double-layer metallic filmsThin Solid Films, 1971
- The resistance of annealed gold films during the nucleation of an evaporated gold overlayerThin Solid Films, 1971
- Determination of submicrogram quantities of mercury by atomic absorption spectrophotometryAnalytical Chemistry, 1968
- Portable atomic absorption photometer for determining nanogram quantities of mercury in the presence of interfering substancesAnalytical Chemistry, 1968
- Influence of a Superimposed Film on the Electrical Conductivity of Thin Metal FilmsJournal of Applied Physics, 1967
- Sensitive simple mercury photometer using mercury resonance lamp as a monochromatic sourceAnalytical Chemistry, 1967
- THE EFFECT OF MERCURY CONTAMINATION ON THE WORK FUNCTION OF GOLDApplied Physics Letters, 1966