4D radial contrast‐enhanced MR angiography with sliding subtraction
Open Access
- 29 October 2007
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 58 (5) , 962-972
- https://doi.org/10.1002/mrm.21364
Abstract
A method is presented for high spatial and temporal resolution 3D contrast‐enhanced magnetic resonance angiography. The overall technique involves a set of interrelated components suited to high‐frame‐rate angiography, including 3D cylindrical k‐space sampling, angular undersampling, asymmetric sampling, sliding window reconstruction, pseudorandom view ordering, and a sliding subtraction mask. Computer simulations and volunteer studies demonstrated the utility of each component of the technique. Angiograms of one hemisphere of the intracranial vasculature were acquired with a pixel size of 1.1 × 1.1 × 2.8 mm and a frame rate of 0.35 sec based on a temporal resolution of 3.5 sec. Such a 3D time‐resolved, or “4D,” technique has the potential to noninvasively acquire diagnostic quality images of certain anatomic regions with a frame rate fast enough to not only ensure the capture of an uncontaminated arterial phase, but even demonstrate contrast bolus flow dynamics. Clinical applications include noninvasive imaging of arteriovenous shunting, which is demonstrated with a patient study. Magn Reson Med 58:962–972, 2007.Keywords
This publication has 36 references indexed in Scilit:
- Self‐navigated motion correction using moments of spatial projections in radial MRIMagnetic Resonance in Medicine, 2004
- High temporal and spatial resolution 4D MRA using spiral data sampling and sliding window reconstructionMagnetic Resonance in Medicine, 2004
- Spatio-temporal bandwidth-based acquisition for dynamic contrast-enhanced magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2004
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- The effects of time varying intravascular signal intensity and k‐space acquisition order on three‐dimensional MR angiography image qualityJournal of Magnetic Resonance Imaging, 1996
- Continuous radial data acquisition for dynamic MRIMagnetic Resonance in Medicine, 1995
- Block Regional Interpolation Scheme for k‐Space (BRISK): A Rapid Cardiac Imaging TechniqueMagnetic Resonance in Medicine, 1995
- “Keyhole” method for accelerating imaging of contrast agent uptakeJournal of Magnetic Resonance Imaging, 1993