Adenosine-Induced Coronary Vasodilatation During Transesophageal Doppler Echocardiography
- 15 July 1995
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 92 (2) , 190-196
- https://doi.org/10.1161/01.cir.92.2.190
Abstract
Background Less invasive methods are replacing traditional invasive means of measuring coronary flow reserve (CFR). Transesophageal echocardiography (TEE) is becoming a useful tool for evaluation of coronary artery disease and has recently been used to measure CFR. This has always been done using dipyridamole, but adenosine has a greater vasodilator potency and more favorable kinetics than dipyridamole. This study was done to evaluate the hypothesis that adenosine is safe, rapid, and accurate in measuring coronary blood flow reserve by TEE Doppler. Methods and Results Forty-nine patients who had recently undergone angiography had a transesophageal echocardiogram with visualization of the coronary arteries and measurement of blood flow velocity in the left anterior descending coronary artery (LAD) during adenosine infusion of 0.14 mg/kg per minute. Angiograms were analyzed by quantitative coronary angiography, and significant stenosis was defined as >70% lumenal diameter narrowing. Thirty-nine of the 49 patients did not have a significant LAD stenosis (group 1); the remainder had significant disease (group 2). Good spectral Doppler recordings of blood flow velocity in the LAD were obtained in 41 of 46 patients (89%). There were no significant differences in baseline coronary blood flow velocities between the two groups. Hyperemic to baseline flow ratios were significantly higher in patients without significant LAD stenosis for peak (2.83±1.04 versus 1.78±0.36) and mean (2.68±0.96 versus 1.75±0.39) diastolic velocity. A CFR ratio >2.1 had a sensitivity of 86%, a specificity of 79%, a positive predictive value of 46%, and a negative predictive value of 96% for the absence of critical LAD stenosis. The infusion was well tolerated. It had to be prematurely terminated in only 3 patients (6.5%), and they were asymptomatic. No patient experienced chest pain, palpitations, or flushing. Intraobserver and interobserver variabilities were low, and reproducibility of data was good (Conclusions Adenosine Doppler TEE is an effective, rapid, safe, and superior means of measuring CFR ratio. This method is convenient for serial measurements of CFR as well as in clinical settings such as evaluation of syndrome X, cardiomyopathy, and aortic regurgitation.Keywords
This publication has 29 references indexed in Scilit:
- Safety profile of adenosine stress perfusion imaging: Results from the adenoscan multicenter trial registryPublished by Elsevier ,2010
- Diagnosis of ischemic heart disease with adenosine echocardiographyJournal of the American College of Cardiology, 1991
- Comparison of coronary vasodilation with intravenous dipyridamole and adenosineJournal of the American College of Cardiology, 1991
- Use of adenosine echocardiography for diagnosis of coronary artery diseaseAmerican Heart Journal, 1991
- Limitations of coronary angiography: An underestimated problem?Clinical Cardiology, 1991
- Assessment of coronary blood flow by transesophageal two-dimensional pulsed Doppler echocardiographyThe American Journal of Cardiology, 1988
- Imaging of coronary arteries by color-coded transesophageal Doppler echocardiographyThe American Journal of Cardiology, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Does Visual Interpretation of the Coronary Arteriogram Predict the Physiologic Importance of a Coronary Stenosis?New England Journal of Medicine, 1984
- Phasic changes in human right coronary blood flow before and after repair of aortic insufficiencyAmerican Heart Journal, 1979