Electrogram Signals Recorded from Acute and Chronic Pacemaker Implantation Sites in Pacemaker Patients
- 1 January 1998
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 21 (1) , 11-17
- https://doi.org/10.1111/j.1540-8159.1998.tb01056.x
Abstract
Electrogram signals recorded from typical pacemaker implantation sites may be useful for a variety of pacemaker system functions including pacemaker follow-up, atrial and ventricular sensing (event detection), and triggered electrogram storage. We quantified the electrical characteristics of pacemaker pocket electrograms using a subcutaneous electrode array (SEA) in a population of 48 patients undergoing initial or replacement pacemaker implantation. SEA recorded intrinsic R wave amplitudes measured peak to peak averaged 118 microV and 65 microV for the two recorded SEA electrograms and were significantly different (P < 0.001); paced R wave amplitudes averaged 180 microV and 110 microV. P wave amplitudes averaged 39 microV and 26 microV. No statistically significant difference in amplitudes were observed between acute versus chronic pacemaker pocket or indication for pacing (AV block, sick sinus syndrome). Signal to noise ratios, using R wave amplitude as signal, were lower in the SEA electrogram on average (11 dB) compared to the intracardiac electrogram (27 dB), but sufficient for diagnostic assessment. R wave/P wave ratios for SEA signals were lower than surface and intracardiac values 3.1 and 2.7 compared to a range of 6.2-9.8, indicating a relative enhancement of P waves to R waves in SEA signals. In summary, SEA electrograms are of sufficient amplitude and signal quality (signal to noise ratio) to hold promise for future implantable device features such as electrogram telemetry, enhanced sensing, and diagnostic data storage.Keywords
This publication has 13 references indexed in Scilit:
- Long‐Term Reliability of Single Lead Atrial Synchronous Pacing Systems Using Closely Spaced Atrial Dipoles: Five‐Year ExperiencePacing and Clinical Electrophysiology, 1994
- Feasibility of an Implantable Arrhythmia MonitorPacing and Clinical Electrophysiology, 1992
- Experience and Implantation Techniques with a New Single‐Pass Lead VDD Pacing SystemPacing and Clinical Electrophysiology, 1990
- Far-Field QRS Complex Sensing Via the Atrial Pacemaker Lead. II. Prevalence, Clinical Significance and Possibility of Intraoperative Prediction in DDD Pacing.Pacing and Clinical Electrophysiology, 1988
- Time Course of Transvenous Pacemaker Stimulation Impedance, Capture Threshold, and Electrogram AmplitudePacing and Clinical Electrophysiology, 1986
- Characteristics of Intracardiac Electrograms II: Atrial Endocardial ElectrogramsPacing and Clinical Electrophysiology, 1980
- Spectral Properties of Atrial and Ventricular Endocardial SignalsPacing and Clinical Electrophysiology, 1979
- Characteristics of Intracardiac Electrograms*Pacing and Clinical Electrophysiology, 1978
- A comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing.Circulation, 1977
- Cardiac pacing and pacemakers III. Sensing the cardiac electrogramAmerican Heart Journal, 1977