Experience of cardioverter-defibrillators inserted without thoracotomy: evaluation of transvenously inserted intracardiac leads alone or with a subcutaneous axillary patch.
Open Access
- 1 January 1993
- Vol. 69 (1) , 14-19
- https://doi.org/10.1136/hrt.69.1.14
Abstract
OBJECTIVES--To compare the efficacy of a purely transvenous cardioverter-defibrillator (ICD) system with that of a system with a supplementary subcutaneous patch. To evaluate clinical follow up of these lead arrangements that do not require thoracotomy. DESIGN--A simplified defibrillation protocol to test two different lead arrangements during implantation, with routine clinical follow up after implantation. SETTING--Tertiary referral centre for treatment of arrhythmia. PATIENTS--22 consecutive patients selected for implantation of an ICD because of life-threatening ventricular arrhythmias (ventricular fibrillation or sustained ventricular tachycardia) of whom 20 entered the test protocol. INTERVENTION--Implantation of an ICD with transvenously inserted intracardiac leads and a subcutaneous patch and assessment of effective defibrillation followed by testing of the purely transvenous approach. MAIN OUTCOME MEASURES--Reproducible conversion of ventricular fibrillation to sinus rhythm at a certain energy level, providing a safety margin of at least 10 J for both lead arrangements. Confirmation of efficacy during clinical follow up (mean 6 months). RESULTS--A transvenous lead system combined with a subcutaneous axillary patch was implanted in 20/22 patients and it provided adequate and acceptable energy levels. In 10/20 tested patients a purely transvenous lead configuration provided an acceptable safety margin as well. Nine patients had clinical recurrences: all these arrhythmias were successfully converted. CONCLUSION--A transvenous lead system was sufficient in 50% of the patients at the time of implantation. Data on long-term clinical follow up of this arrangement are not available. The approach without thoracotomy with a subcutaneous patch is feasible and effective in most patients selected for ICD treatment.Keywords
This publication has 16 references indexed in Scilit:
- Is Defibrillation Testing Safe?Pacing and Clinical Electrophysiology, 1991
- Patients with a high defibrillation threshold: Clinical characteristics, management, and outcomeAmerican Heart Journal, 1991
- The Initial Clinical Experience with an Implantable Cardioverter Defibrillator/ Antitachycardia PacemakerPacing and Clinical Electrophysiology, 1991
- Experience with a third-generation implantable cardioverter-defibrillatorThe American Journal of Cardiology, 1991
- Transvenous catheter defibrillation for prevention of sudden cardiac deathJournal of the American College of Cardiology, 1988
- Comparison of defibriliation efficacy in humans using a new catheter and superior vena cava spring-left ventricular patch electrodesJournal of the American College of Cardiology, 1988
- When “sudden cardiac death” is not so sudden:Lessons learned from the automatic implantable defibrillatorAmerican Heart Journal, 1988
- EXPERIENCE WITH AN AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATORThe Lancet, 1987
- Early Experience with an Implantable CardioverterNew England Journal of Medicine, 1984
- Measurement of cardioversion/defibrillation thresholds in man by a truncated exponential waveform and an apical patch-superior vena caval spring electrode configuration.Circulation, 1984