Several studies have uniformly demonstrated a marked reduction in expected arrhythmic/sudden death rates in patients with either drug-refractory sustained ventricular tachycardia, ventricular fibrillation or survivors of cardiac arrest following the implantation of cardioverter-defibrillators (ICD). Significant advances in these devices over the past 10 years have permitted programmability and demand pacing. There has been sophistication in tachycardia detection and the characteristics of the delivered electrical therapy. Programs to reconfirm the arrhythmic event, sensing parameters for rate, electrogram amplitude, data storage, interrogation and morphology are available in some devices. Some models will permit both antitachycardia pacing as well as defibrillation functions and choice of shock waveforms as bidirectional and biphasic shocks. Endocardial lead systems using smaller and more flexible electrodes may obliterate the need for thoracotomy. It appears that ICD therapy will form a significant component in antiarrhythmic therapy in the future.This publication has 8 references indexed in Scilit:
- Clinical efficacy of dual electrode systems for endocardial cardioversion of ventricular tachycardia: A prospective randomized crossover trialAmerican Heart Journal, 1990
- Initial clinical experience with endocardial defibrillation using an implantable cardioverter/defibrillator with a triple-electrode systemArchives of internal medicine (1960), 1989
- Predictors of total mortality and sudden death in mild to moderate heart failureJournal of the American College of Cardiology, 1989
- Improved low energy defibrillation efficacy in man with the use of a biphasic truncated exponential waveformAmerican Heart Journal, 1989
- Usefulness of an implantable antitachycardia pacemaker system for supraventricular or ventricular tachycardiaThe American Journal of Cardiology, 1986
- Internal cardiac defibrillation in man: pronounced improvement with sequential pulse delivery to two different lead orientations.Circulation, 1986
- A prospective randomized study of the clinical efficacy and safety of transvenous cardioversion for termination of ventricular tachycardia.Circulation, 1985
- Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator.Circulation, 1985