Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes
- 1 November 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 27 (11) , 1823-1828
- https://doi.org/10.1016/s0886-3350(01)01089-6
Abstract
To compare corneal thickness measurements made by ultrasonic and slit-scanning techniques in normal eyes and in eyes after laser in situ keratomileusis (LASIK). Corneal Diseases and Excimer Laser Research Unit, University of Dundee, Dundee, Scotland. Central corneal thickness (CCT) was measured in 101 eyes of 59 normal subjects and in 30 eyes of 21 post-LASIK patients. Measurements were made with an Orbscan slit-scanning elevation topographer and immediately afterward with an ultrasound pachymeter. The difference in mean CCT between ultrasound (538.0 microm +/- 36.7 [SD]) and Orbscan (566.6 +/- 40.7 microm) pachymetry was statistically significant (P <.001) in the normal eyes; the Orbscan measurement was approximately 28 microm higher than that of the ultrasound pachymeter. The difference in mean CCT between the ultrasound and the slit-scanning techniques was also statistically significant in the post-LASIK eyes (mean values 475.3 +/- 50.3 microm and 461.9 +/- 74.2 microm, respectively; P <.0001). Differences in CCT in individual subjects were much more variable in the post-LASIK eyes than in the normal eyes. The Bland and Altman method for assessing clinical agreement between 2 instruments showed that in 95% of cases, the CCT measurements with both instruments would be within 65 microm in normal eyes and 150 microm in post-LASIK eyes. Central corneal thickness measurements were, on average, 28 microm higher with the Orbscan than with the ultrasound pachymeter in normal eyes and 13 microm lower in post-LASIK eyes. The degree of variability within each group indicated that these 2 techniques are not clinically comparable, precluding interchangeable use of their data in planning or assessing corneal surgery.Keywords
This publication has 10 references indexed in Scilit:
- A Model to Explain the Difference Between Changes in Refraction and Central Ocular Surface Power After Laser in situ KeratomileusisJournal of Refractive Surgery, 2000
- Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography systemBritish Journal of Ophthalmology, 1999
- Orbscan pachymetry: Implications of a repeated measures and diurnal variation analysisOphthalmology, 1999
- Regular and Irregular Refractive Powers of the Front and Back Surfaces of the CorneaExperimental Eye Research, 1998
- Ultrasound biomicroscopic localization and evaluation of intraocular foreign bodiesActa Ophthalmologica Scandinavica, 1998
- KeratoconusSurvey of Ophthalmology, 1998
- Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetryJournal of Cataract & Refractive Surgery, 1997
- Comparison of efficacy of longest, average, and shortest axial length measurements with a solid-tip ultrasound probe in predicting intraocular lens powerJournal of Cataract & Refractive Surgery, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- ON THE OPTICAL MEASUREMENT OF CORNEAL THICKNESSActa Ophthalmologica, 1980