Two- and four-coil phased array detectors were developed to increase the sensitivity and resolution of MR imaging of the human brain cortex, especially for detecting cortical dysplasias in pediatric epilepsy patients. An automated intensity correction algorithm based on an edge-completed, low-pass filtered image was used to correct the image intensity for the inhomogenous reception profile of the coils. Seven phased array coils were constructed and tested. The sensitivity of these coils was up to 600% higher at the surface of the cortex than that achieved with a conventional head coil and up to 30% greater at the center of the head. The sensitivity obtained was comparable with that of a conventional small surface coil, but extended over the larger dimensions of the array and previously inaccessible areas such as the top of the head. The advantages of the improved sensitivity are demonstrated with high resolution images of the brain.Keywords
This publication has 21 references indexed in Scilit:
- Surface coil MR imaging of the human brain with an analytic reception profile correctionJournal of Magnetic Resonance Imaging, 1995
- The fornix in patients with seizures caused by unilateral hippocampal sclerosis: detection of unilateral volume loss on MR images.American Journal of Roentgenology, 1994
- Single‐breath‐hold venous or arterial flow‐suppressed pulmonary vascular MR imaging with phased‐array coilsJournal of Magnetic Resonance Imaging, 1993
- An NMR Phased Array for Human Cardiac 31P SpectroscopyMagnetic Resonance in Medicine, 1992
- Pelvic imaging with phased‐array coils: Quantitative assessment of signal‐to‐noise ratio improvementJournal of Magnetic Resonance Imaging, 1992
- Pulmonary MR Angiography Utilizing Phased-Array Surface CoilsJournal of Computer Assisted Tomography, 1992
- Focal neuronal migration disorders and intractable partial epilepsy: A study of 30 patientsAnnals of Neurology, 1991
- Volume imaging with MR phased arraysMagnetic Resonance in Medicine, 1991
- Intensity correction in surface-coil MR imagingAmerican Journal of Roentgenology, 1987
- Electronic decoupling of surface-coil receivers for NMR imaging and spectroscopyJournal of Magnetic Resonance (1969), 1986