Abstract
It has been claimed that speech recognition with a cochlear implant is dependent on the frequency alignment of analysis bands in the speech processor with characteristic frequencies (CFs) at electrode locations. However, the most apical electrode location can often have a CF of 1 kHz or more. The use of filters aligned in frequency to relatively basal electrode arrays leads to the loss of lower frequency speech information. This study simulates a frequency-aligned speech processor and common array insertion depths to assess this significance of this loss. Noise-excited vocoders simulated processors driving eight electrodes 2 mm apart. Analysis filters always had center frequencies matching the CFs of the simulated stimulation sites. The simulated insertion depth of the most apical electrode was varied in 2-mm steps between 25 mm (CF 502 Hz) and 17 mm (CF 1851 Hz) from the cochlear base. Identification of consonants, vowels, and words in sentences all showed a significant decline between each of the three more basal simulated electrode configurations. Thus, if implant processors used analysis filters frequency-aligned to electrode CFs, patients whose most apical electrode is 19 mm (CF 1.3 kHz) or less from the cochlear base would suffer a significant loss of speech information.Keywords
This publication has 15 references indexed in Scilit:
- Perceptual learning following changes in the frequency-to-electrode assignment with the Nucleus-22 cochlear implantThe Journal of the Acoustical Society of America, 2002
- The Importance of Human Cochlear Anatomy for the Results of Modiolus-Hugging Multichannel Cochlear ImplantsOtology & Neurotology, 2001
- Perceptual “vowel spaces” of cochlear implant users: Implications for the study of auditory adaptation to spectral shiftThe Journal of the Acoustical Society of America, 2001
- Effects of Electrode Location and Spacing on Phoneme Recognition with the Nucleus-22 Cochlear ImplantEar & Hearing, 1999
- Recognition of spectrally degraded and frequency-shifted vowels in acoustic and electric hearingThe Journal of the Acoustical Society of America, 1999
- Simulating the effect of cochlear-implant electrode insertion depth on speech understandingThe Journal of the Acoustical Society of America, 1997
- Lip-reading the BKB sentence lists: Corrections for list and practice effectsBritish Journal of Audiology, 1993
- A cochlear frequency-position function for several species—29 years laterThe Journal of the Acoustical Society of America, 1990
- A method for training and evaluating the reception of ongoing speechThe Journal of the Acoustical Society of America, 1978
- Factors Governing the Intelligibility of Speech SoundsThe Journal of the Acoustical Society of America, 1947