Collateral flow in coarctation of the aorta with magnetic resonance velocity mapping: Correlation to morphological imaging of collateral vessels
Open Access
- 7 January 2002
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 15 (1) , 39-46
- https://doi.org/10.1002/jmri.10036
Abstract
Purpose To correlate quantification of collateral flow in aortic coarctation with the morphological visualization of the collateral vessels and to compare different approaches to measurement of collateral flow. Materials and Methods Thirteen children with coarctation were examined with T1‐weighted spin‐echo (T1‐W SE) imaging and 3D contrast‐enhanced magnetic resonance angiography (MRA). MR velocity mapping was performed at four levels in the descending aorta. Results The flow immediately above and below the coarctation did not differ significantly. Measuring within the coarctation resulted in flow overestimation. The increase of flow from proximal to distal aorta was 12 ± 21% in patients with no or uncertain collaterals and 69 ± 55% in patients with pronounced collaterals. Spin‐echo images and MRA were comparable in visualizing collateral vessels. The visual estimation of collaterals correlated reasonably well with flow quantification MR velocity mapping. Conclusion Collateral flow assessment with MR velocity mapping is an accurate technique for evaluating the hemodynamic importance of a coarctation and is recommended if abundant collaterals are not visualized with spin echo or MRA. J. Magn. Reson. Imaging 2002;15:39–46.Keywords
This publication has 31 references indexed in Scilit:
- In Vivo Validation of Magnetic Resonance Blood Volume Flow Measurements with Limited Spatial Resolution in Small VesselsMagnetic Resonance in Medicine, 1995
- Pulse sequence design for MR velocity mapping of complex flow: Notes on the necessity of low echo timesMagnetic Resonance Imaging, 1994
- Magnetic resonance volume flow and jet velocity mapping in aortic coarctationJournal of the American College of Cardiology, 1993
- Analysis of systematic and random error in MR volumetric flow measurementsMagnetic Resonance in Medicine, 1993
- Accuracy of phase‐contrast flow measurements in the presence of partial‐volume effectsJournal of Magnetic Resonance Imaging, 1993
- Continuous wave Doppler echocardiography and coarctation of the aorta: gradients and flow patterns in the assessment of severity.Heart, 1990
- Magnetic resonance imaging of coarctation of the aorta in infants: use of a high field strength.Heart, 1989
- Accuracy of two-dimensional echocardiography in the diagnosis of aortic arch obstructionJournal of the American College of Cardiology, 1987
- Accuracy and pitfalls of Doppler evaluation of the pressure gradient in aortic coarctationJournal of the American College of Cardiology, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986