Left Ventricular and Myocardial Perfusion Responses to Volume Unloading and Afterload Reduction in a Computer Simulation
- 1 September 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 50 (5) , 512-518
- https://doi.org/10.1097/01.mat.0000136513.21369.75
Abstract
Ventricular assist devices (VADs) have been used successfully as a bridge to transplant in heart failure patients by unloading ventricular volume and restoring the circulation. In a few cases, patients have been successfully weaned from these devices after myocardial recovery. To promote myocardial recovery and alleviate the demand for donor organs, we are developing an artificial vasculature device (AVD) that is designed to allow the heart to fill to its normal volume but eject against a lower afterload. Using this approach, the heart ejects its stroke volume (SV) into an AVD anastomosed to the aortic arch, which has been programmed to produce any desired afterload condition defined by an input impedance profile. During diastole, the AVD returns this SV to the aorta, providing counterpulsation. Dynamic computer models of each of the assist devices (AVD, continuous, and pulsatile flow pumps) were developed and coupled to a model of the cardiovascular system. Computer simulations of these assist techniques were conducted to predict physiologic responses. Hemodynamic parameters, ventricular pressure-volume loops, and vascular impedance characteristics were calculated with AVD, continuous VAD, and asynchronous pulsatile VAD support for a range of clinical cardiac conditions (normal, failing, and recovering left ventricle). These simulation results indicate that the AVD may provide better coronary perfusion, as well as lower vascular resistance and elastance seen by the native heart during ejection compared with continuous and pulsatile VAD. Our working hypothesis is that by controlling afterload using the AVD approach, ventricular cannulation can be eliminated, myocardial perfusion improved, myocardial compliance and resistance restored, and effective weaning protocols developed that promote myocardial recovery.Keywords
This publication has 25 references indexed in Scilit:
- Left ventricular assist device-induced reverse ventricular remodelingProgress in Cardiovascular Diseases, 2000
- Results with the Novacor assist system and evaluation of long-term assistance✩European Journal of Cardio-Thoracic Surgery, 2000
- The Odyssey of the Artificial HeartArtificial Organs, 2000
- Development of Rotary Blood Pump Technology: Past, Present, and FutureArtificial Organs, 2000
- Decreased Expression of Tumor Necrosis Factor-α in Failing Human Myocardium After Mechanical Circulatory SupportCirculation, 1999
- Increased Superoxide in Heart FailureCirculation, 1999
- Sixth International Symposium for Rotary Blood PumpsArtificial Organs, 1999
- Myocyte Recovery After Mechanical Circulatory Support in Humans With End-Stage Heart FailureCirculation, 1998
- Left ventricular assist devices: current status and future applicationsInternational Journal of Cardiology, 1997
- Reversal of Chronic Ventricular Dilation in Patients With End-Stage Cardiomyopathy by Prolonged Mechanical UnloadingCirculation, 1995